Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 228

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A luminous efficiency function,V*(λ), for daylight adaptation

Open access
Sharpe, Lindsay T., Stockman, Andrew, Jagla, Wolfgang, Jägle, Herbert · 2005 · Journal of Vision

Abstract

We propose a new luminosity function, V*(lambda), that improves upon the original CIE 1924 V(lambda) function and its modification by D. B. Judd (1951) and J. J. Vos (1978), while being consistent with a linear combination of the A. Stockman & L. T. Sharpe (2000) long-wavelength-sensitive (L) and middle-wavelength-sensitive (M) cone fundamentals. It is based on experimentally determined 25 Hz, 2 degrees diameter, heterochromatic (minimum) flicker photometric data obtained from 40 observers (35 males, 5 females) of known genotype, 22 with the serine variant L(ser180), 16 with the alanine L(ala180) variant, and 2 with both variants of the L-cone photopigment. The matches, from 425 to 675 nm in 5-nm steps, were made on a 3 log troland xenon white (correlated color temperature of 5586 K but tritanopically metameric with CIE D65 standard daylight for the Stockman and Sharpe L- and M-cone fundamentals in quantal units) adapting field of 16 degrees angular subtense, relative to a 560-nm standard. Both the reference standard and test lights were kept near flicker threshold so that, in the region of the targets, the total retinal illuminance averaged 3.19 log trolands. The advantages of the new function are as follows: it forms a consistent set with the new proposed CIE cone fundamentals (which are the Stockman & Sharpe 2000 cone fundamentals); it is based solely on flicker photometry, which is the standard method for defining luminance; it corresponds to a central 2 degrees viewing field, for which the basic laws of brightness matching are valid for flicker photometry; its composition of the serine/alanine L-cone pigment polymorphism (58:42) closely matches the reported incidence in the normal population (56:44; Stockman & Sharpe, 1999); and it specifies luminance for a reproducible, standard daylight condition. V*(lambda) is defined as 1.55L(lambda) + M(lambda), where L(lambda) and M(lambda) are the Stockman & Sharpe L- & M-cone (quantal) fundamentals. It is extrapolated to wavelengths shorter than 425 nm and longer than 675 nm using the Stockman & Sharpe cone fundamentals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/5.11.3

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Spectral transmission of the human ocular media

    Norren, D. V., & Vos, J. J. (1974) · Vision Research · doi:10.1016/0042-6989(74)90222-3 · Cited by 377 · cited 2×

    “The lens pigment density scaling estimates correspond to the amount the lens pigment density spectrum template ½dlensð1Þ of van Norren & Vos (1974), slightly modified by Stockman et al. (1993) and Stockman & Sharpe (1999), has to be weighted to adjust to the observer’s own lens pigment density.”

Show all 1 references

Cited by

Metadata

Authors
Sharpe, L. T., Stockman, A., Jagla, W., & Jägle, H.
Venue
Journal of Vision
Published
2005-12-21
Volume
5
Issue
11
Pages
3
ISSN
1534-7362 (ISSN-L)
OpenAlex
W2062448889
Cited by
228
References
1
FWCI
2.66
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.