Latency of the Pupil Light Reflex: Sample Rate, Stimulus Intensity, and Variation in Normal Subjects
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PURPOSE: To investigate the clinical usefulness of the latency of the pupil light reflex by optimizing its measurement, characterizing its variability, and determining the sensitivity of pupil latency as a function of stimulus input in normal subjects. METHODS: Computerized binocular infrared pupillography was performed in 14 eyes of seven healthy subjects. Pupils were recorded simultaneously at 60 and 1000 Hz. Each eye was alternatively stimulated eight times for 50 ms every 2.5 seconds, increasing by 0.5 log units over a 2.0-log-unit range. To determine intersubject and intereye variability, 98 eyes of 49 healthy subjects were recorded at 60 Hz over a 3.0-log-unit range (15 degrees radius stimulation, four repetitions at each intensity). RESULTS: Accuracy and resolution of latency were limited by the number of light reflexes used to estimate the average latency and were significantly affected by sampling rate when the number of reflexes recorded was fewer than four. Binocular recording and interpolation of the 60-Hz recording to 300 Hz added resolution to the latency. Biological variability contributed more to interindividual variability than did measurement variability. The range of intereye afferent asymmetry of latency in normal subjects was only between 8.3 and 35 ms-less with brighter stimulus intensity. CONCLUSIONS: An optimal method for determination of the onset of the pupil light reflex was devised that consisted of filtering, interpolation of pupil recordings, and analysis of the first and second derivative of the pupil movement. Most of the variability in latency as a function of intensity in normal subjects was due to interindividual variation and latency was well matched between the two eyes of the subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Cited by
Safety and Efficacy of Gene Transfer for Leber's Congenital Amaurosis
Maguire, A. M., Simonelli, F., Pierce, E. A., Pugh, E. N., Mingozzi, F., Bennicelli, J., Banfi, S., Marshall, K. A., Testa, F., Surace, E. M., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0802315 · Cited by 2,145
Maguire, A. M., High, K. A., Auricchio, A., Wright, J. F., Pierce, E. A., Testa, F., Mingozzi, F., Bennicelli, J. L., Ying, G.-S., Rossi, S., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61836-5 · Cited by 865
Park, J. C., Moura, A. L., Raza, A. S., Rhee, D. W., Kardon, R. H., & Hood, D. C. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-7586 · Cited by 259
Self-citationAbnormal transient pupillary light reflex in individuals with autism spectrum disorders
Fan, X., Miles, J. H., Takahashi, N., & Yao, G. (2009) · Journal of Autism and Developmental Disorders · doi:10.1007/s10803-009-0767-7 · Cited by 121
Shi, Y., Du, J., & Worthy, D. A. (2020) · Automation in Construction · doi:10.1016/j.autcon.2020.103367 · Cited by 82
Metadata
- Authors
- Bergamin, O., & Kardon, R. H.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2003-04-01
- Volume
- 44
- Issue
- 4
- Pages
- 1546
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2076016420
- Cited by
- 154
- References
- 1
- FWCI
- 3.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.