Feasibility of Drug Delivery to the Posterior Pole of the Rabbit Eye with an Episcleral Implant
The DOI matches its Crossref record.
Abstract
PURPOSE: To evaluate the feasibility of a nonbiodegradable polymeric episcleral implant as a new controlled intraocular delivery system of betamethasone (BM) to the posterior pole of the eye. METHODS: The episcleral implant, which is composed of a drug-releasing component and a suture tag, released BM through an ethylene vinyl acetate membrane. The implants were placed on the sclera in 12 eyes of 12 Japanese white rabbits so that the drug-releasing surface could attach to the sclera at the posterior pole. BM concentrations in the aqueous humor, vitreous, and retina-choroid (posterior half and anterior half) were determined by high-performance liquid chromatography (HPLC) at weeks 1, 2, and 4 after implantation. In addition, the intraocular tissue distribution of the drug was evaluated by fluorescein microscopy after implantation of the implant loaded with 6-carboxy fluorescein diacetate (6-CFDA) as a drug marker. Retinal toxicity was evaluated by electroretinography and histologic examination. RESULTS: The implant showed zero-order release profiles both in vitro and in vivo for 4 weeks. BM concentrations in the retina-choroid after implantation were maintained above the concentrations effective for suppressing inflammatory reactions for at least 4 weeks. The BM concentration was greater in the posterior half of the retina-choroid than in the vitreous. It was confirmed that 6-CFDA penetrated through the sclera and dispersed into the retina-choroid. Fluorescence from 6-CFDA gradually decreased in intensity with increased distance from the implantation site. Electroretinography and histologic study showed no substantial toxic reactions. CONCLUSIONS: These findings suggest that the episcleral implant may be a useful drug carrier for intraocular delivery of BM, especially for the posterior part of the eye.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent Perspectives in Ocular Drug Delivery
Gaudana, R., Jwala, J., Boddu, S. H. S., & Mitra, A. K. (2009) · Pharmaceutical Research · doi:10.1007/s11095-008-9694-0 · Cited by 605
Current and future ophthalmic drug delivery systems
del Amo, E. M., & Urtti, A. (2008) · Drug Discovery Today · doi:10.1016/j.drudis.2007.11.002 · Cited by 414
Drug delivery to the posterior segment of the eye
Thrimawithana, T. R., Young, S., Bunt, C. R., Green, C., & Alany, R. G. (2011) · Drug Discovery Today · doi:10.1016/j.drudis.2010.12.004 · Cited by 335
Permeability of Retinal Pigment Epithelium: Effects of Permeant Molecular Weight and Lipophilicity
Pitka¨nen, L., Ranta, V.-P., Moilanen, H., & Urtti, A. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1051 · Cited by 261
“, growth factors or antiangiogenic agents), and gene medicines to the retina.(2,5) In those cases, the drug should permeate the sclera, choroid, and RPE.”
BackgroundNanomedicines for back of the eye drug delivery, gene delivery, and imaging
Kompella, U. B., Amrite, A. C., Pacha Ravi, R., & Durazo, S. A. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2013.04.001 · Cited by 258
Periocular routes for retinal drug delivery
Raghava, S., Hammond, M., & Kompella, U. B. (2004) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.1.1.99 · Cited by 257
Intraocular implants for extended drug delivery: Therapeutic applications
Bourges, J. L., Bloquel, C., Thomas, A., Froussart, F., Bochot, A., Azan, F., Gurny, R., BenEzra, D., & Behar-Cohen, F. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.07.026 · Cited by 235
Nanotherapy for posterior eye diseases
Kaur, I. P., & Kakkar, S. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.031 · Cited by 175
Transport Barriers in Transscleral Drug Delivery for Retinal Diseases
Kim, S. H., Lutz, R. J., Wang, N. S., & Robinson, M. R. (2007) · Ophthalmic Research · doi:10.1159/000108117 · Cited by 172
MYLES, M., NEUMANN, D., & HILL, J. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2005.08.006 · Cited by 171
Transscleral drug delivery to the posterior eye: Prospects of pharmacokinetic modeling
Ranta, V.-P., & Urtti, A. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.07.025 · Cited by 160
Metadata
- Authors
- Kato, A., Kimura, H., Okabe, K., Okabe, J., Kunou, N., & Ogura, Y.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2004-01-01
- Volume
- 45
- Issue
- 1
- Pages
- 238
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2023936996
- Cited by
- 66
- References
- 0
- FWCI
- 2.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.