The DOI matches its Crossref record.
Aqueous Humor Dynamics in Mice
Abstract
PURPOSE: To assess aqueous humor dynamics in mouse eyes. METHODS: Aqueous humor dynamics of NIH Swiss White mouse were assessed with an injection and aspiration system, using fine glass microneedles. Intraocular pressure (IOP) was measured by a microneedle connected to a pressure transducer. Episcleral venous pressure (EVP) was measured by gradually lowering intracameral pressure until blood reflux into Schlemm's canal was observed. Outflow facility (C) was determined based on constant pressure perfusion measurements obtained at two different IOPs. Aqueous volume (V(a)) was determined by direct measurement of aspirated aqueous humor. Aqueous humor production (F(a)) was measured by the dilution method with rhodamine-dextran. Conventional and uveoscleral outflow (F(c) and F(u), respectively), as well as the turnover rate of aqueous humor, were also calculated. RESULTS: IOP and EVP were 15.7 +/- 2.0 and 9.5 +/- 1.2 mm Hg, respectively (n = 20). F(a) was 0.18 +/- 0.05 microL/min (mean +/- SD; n = 8). C was 0.0051 +/- 0.0006 microL/min per mm Hg (n = 8). Estimated F(c) and F(u) were 0.032 and 0.148 microL/min, respectively. F(c) was 18% of F(a). F(u) was 82% of F(a). V(a) was 5.9 +/- 0.5 microL (n = 8). The calculated turnover rate of aqueous humor was 2.5%. CONCLUSIONS: The mouse eye has similar aqueous production and aqueous humor turnover rate as the human eye. The presence of both conventional and uveoscleral outflow suggests that the mouse is a useful model system for further investigations of the biology of aqueous dynamics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pharmacokinetic aspects of retinal drug delivery
del Amo, E. M., Rimpelä, A.-K., Heikkinen, E., Kari, O. K., Ramsay, E., Lajunen, T., Schmitt, M., Pelkonen, L., Bhattacharya, M., Richardson, D., et al. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.12.001 · Cited by 693
Update on the Mechanism of Action of Topical Prostaglandins for Intraocular Pressure Reduction
Toris, C. B., Gabelt, B. T., & Kaufman, P. L. (2008) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2008.08.010 · Cited by 311
Lin, S., Ge, C., Wang, D., Xie, Q., Wu, B., Wang, J., Nan, K., Zheng, Q., & Chen, W. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b13851 · Cited by 88
Metadata
- Authors
- Aihara, M., Lindsey, J. D., & Weinreb, R. N.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2003-12-01
- Volume
- 44
- Issue
- 12
- Pages
- 5168
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2085448595
- Cited by
- 174
- References
- 0
- FWCI
- 4.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Aqueous Humor Dynamics in Mice. https://app.cochat.ai/papers/10.1167/iovs.03-0504
- The paper
- Aihara, M., Lindsey, J. D., & Weinreb, R. N. (2003). Aqueous Humor Dynamics in Mice. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.03-0504
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.