CoChat

Uncoupling Keratocyte Loss of Corneal Crystallin from Markers of Fibrotic Repair

Stramer, Brian M., Fini, M. Elizabeth · 2004 · Investigative Opthalmology & Visual Science
Cited by 35

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

PURPOSE: Corneal crystallins are lost from resident cells of the corneal stroma during wound repair, and this is associated with a loss of cell transparency. The goal of this study was to identify factors inducing loss of the corneal crystallin transketolase (TKT). METHODS: A cell culture model of freshly isolated rabbit corneal keratocytes was used. Fibrotic markers included cell proliferation, adoption of a "fibroblastic" spindle-shaped morphology associated with cytoskeletal rearrangement, loss of TKT, and expression of alpha-smooth muscle actin (alpha-sm actin), a marker for the myofibroblast. RESULTS: When freshly isolated keratocytes were cultured in the continuous presence of 10% calf serum, the high level of intracellular TKT protein was reduced dramatically within 24 to 48 hours. In contrast, TKT protein was retained in cells maintained in the absence of serum. When cells were prevented from proliferating by exposure to serum for <24 hours or by continuously exposing to serum at a contact-inhibiting plating density, TKT loss was inhibited. TKT loss was induced by treatment of serum-free cultures with the serum cytokines platelet-derived growth factor or basic fibroblast growth factor, both of which also stimulated keratocyte proliferation, although not other changes associated with fibrosis. However, TKT loss was not induced by treatment of serum-free cultures with a third serum cytokine, transforming growth factor- (TGF)-beta, even though TGF-beta stimulated cell proliferation at low doses and induced the fibroblastic spindle-shape and express alpha-sm actin at high doses. CONCLUSIONS: TKT loss in corneal keratocytes can be induced by PDGF or bFGF and this loss can be uncoupled from other fibrotic markers. Targeting these cytokines or the signaling pathways that they activate could enable retention of corneal crystallin in stromal cells during repair, a more regenerative outcome. The result would be enhanced clarity of the cornea.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.03-1057

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Stramer, B. M., & Fini, M. E.
Venue
Investigative Opthalmology & Visual Science
Published
2004-11-01
Volume
45
Issue
11
Pages
4010
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W1977649843
Cited by
35
References
1
FWCI
1.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.