The DOI matches its Crossref record.
Three-Dimensional Ultrahigh-Resolution Optical Coherence Tomography of Macular Diseases
Abstract
PURPOSE: To demonstrate a new generation of three-dimensional (3-D) ultrahigh-resolution optical coherence tomography (UHR OCT) technology for visualization of macular diseases. METHODS: One hundred forty eyes with a distinct disease in each of the posterior pole compartments were examined with 3-D UHR OCT. 3-D imaging was performed with a high axial resolution of 3 mum with a compact, commercially available, ultra-broad-bandwidth (160 nm) titanium:sapphire laser at a video rate of up to 25 B-scans/s. Each tomogram consisted of 1024 x 1024 pixels, resulting in 25 megavoxels/s. RESULTS: 3-D UHR OCT offers high-precision 3-D visualization of macular diseases at all structural levels. The UHR modality allows identification of the contour of the hyaloid membrane, tractive forces of epiretinal membranes, and changes within the inner limiting membrane. The system provides quality 3-D images of the topographic dynamics of traction lines from the retinal surface down to the level of the photoreceptor segments. Intraretinal diseases are identified by their specific location in different layers of the neurosensory ultrastructure. Photoreceptor inner and outer segments are clearly delineated in configuration and size, with a characteristic peak in the subfoveal area. The microarchitecture of choroidal neovascularization is distinctly imaged, related leakage can be identified, and the volume can be quantified. CONCLUSIONS: High-speed UHR OCT offers unprecedented, realistic, 3-D imaging of ocular diseases at all epi-, intra- and subretinal levels. A complete 3-D data set of the macular layers allows a comprehensive analysis of focal and diffuse diseases, as well as identification of dynamic pathomechanisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Optical Coherence Tomography: History, Current Status, and Laboratory Work
Gabriele, M. L., Wollstein, G., Ishikawa, H., Kagemann, L., Xu, J., Folio, L. S., & Schuman, J. S. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6312 · Cited by 310
Srinivasan, V. J., Monson, B. K., Wojtkowski, M., Bilonick, R. A., Gorczynska, I., Chen, R., Duker, J. S., Schuman, J. S., & Fujimoto, J. G. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0838 · Cited by 277
Schmidt-Erfurth, U., Waldstein, S. M., Deak, G.-G., Kundi, M., & Simader, C. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2014.11.017 · Cited by 211
Self-citation
Metadata
- Authors
- Schmidt-Erfurth, U.
- Venue
- Investigative Ophthalmology & Visual Science
- Published
- 2005-09-01
- Volume
- 46
- Issue
- 9
- Pages
- 3393-3402
- ISSN
- 0146-0404 (ISSN-L)
- OpenAlex
- W2132090774
- Cited by
- 271
- References
- 0
- FWCI
- 18.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-Dimensional Ultrahigh-Resolution Optical Coherence Tomography of Macular Diseases. https://app.cochat.ai/papers/10.1167/iovs.05-0370
- The paper
- Schmidt-Erfurth, U. (2005). Three-Dimensional Ultrahigh-Resolution Optical Coherence Tomography of Macular Diseases. Investigative Ophthalmology & Visual Science. https://doi.org/10.1167/iovs.05-0370
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.