The DOI matches its Crossref record.
Binocular Summation of Contrast Remains Intact in Strabismic Amblyopia
Open accessAbstract
PURPOSE: Strabismic amblyopia is typically associated with several visual deficits, including loss of contrast sensitivity in the amblyopic eye and abnormal binocular vision. Binocular summation ratios (BSRs) are usually assessed by comparing contrast sensitivity for binocular stimuli (sens(BIN)) with that measured in the good eye alone (sens(GOOD)), giving BSR = sens(BIN)/sens(GOOD). This calculation provides an operational index of clinical binocular function, but does not assess whether neuronal mechanisms for binocular summation of contrast remain intact. This study was conducted to investigate this question. METHODS: Horizontal sine-wave gratings were used as stimuli (3 or 9 cyc/deg; 200 ms), and the conventional method of assessment (above) was compared with one in which the contrast in the amblyopic eye was adjusted (normalized) to equate monocular sensitivities. RESULTS: In nine strabismic amblyopes (mean age, 32 years), the results confirmed that the BSR was close to unity when the conventional method was used (little or no binocular advantage), but increased to approximately radical2 or higher when the normalization method was used. The results were similar to those for normal control subjects (n = 3; mean age, 38 years) and were consistent with the physiological summation of contrast between the eyes. When the normal observers performed the experiments with a neutral-density (ND) filter in front of one eye, their performance was similar to that of the amblyopes in both methods of assessment. CONCLUSIONS: The results indicate that strabismic amblyopes have mechanisms for binocular summation of contrast and that the amblyopic deficits of binocularity can be simulated with an ND filter. The implications of these results for best clinical practice are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Amblyopia and binocular vision
Birch, E. E. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.11.001 · Cited by 539
Perceptual learning as a potential treatment for amblyopia: A mini-review
Levi, D. M., & Li, R. W. (2009) · Vision Research · doi:10.1016/j.visres.2009.02.010 · Cited by 402
Binocular visual performance and summation after correcting higher order aberrations
Sabesan, R., Zheleznyak, L., & Yoon, G. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.003176 · Cited by 59
Xiao, S., Gaier, E. D., Mazow, M. L., Stout, A. U., Travers, D. A., Angjeli, E., Wu, H. C., Binenbaum, G., & Hunter, D. G. (2020) · Scientific Reports · doi:10.1038/s41598-020-65234-3 · Cited by 44
Metadata
- Authors
- Baker, D. H., Meese, T. S., Mansouri, B., & Hess, R. F.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2007-11-01
- Volume
- 48
- Issue
- 11
- Pages
- 5332
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1975460162
- Cited by
- 206
- References
- 0
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.