CoChat

Evaluation of Ranibizumab-Induced Changes in High-Resolution Optical Coherence Tomographic Retinal Morphology and Their Impact on Visual Function

Kiss, Christopher G., Geitzenauer, Wolfgang, Simader, Christian, Gregori, Giovanni, Schmidt-Erfurth, Ursula · 2009 · Investigative Opthalmology & Visual Science
Cited by 65

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

PURPOSE: To evaluate the effects of intravitreal ranibizumab on retinal function and morphology and to identify a correlation between anatomy and function by using spectral domain optical coherence tomography (SDOCT). METHODS: Twenty-three patients affected by neovascular AMD received three injections of ranibizumab in three consecutive months and were monitored by assessment of best corrected visual acuity (BCVA), central retinal sensitivity (CRS) and morphologic changes at the level of the retina and the retinal pigment epithelium (RPE). The morphologic changes, identified by SDOCT segmentation, were mean retinal thickness (MRT), central retinal thickness (CRT), and the pathologic area (lesion area) of the RPE. RESULTS: BCVA increased from a mean 60.1 +/- 8.7 letters at baseline to 67.0 +/- 10.9 at month 3 (P = 0.0003). The CRS at the 0 degrees position increased from 2.8 +/- 3.1 dB at baseline to 4.0 +/- 5.7 at week 1, remaining stable until month 3. Absolute scotoma size decreased continuously from baseline to month 3, in a mean of 5.3 +/- 5.8 to 3.6 +/- 4.0 test point locations. By SDOCT, MRT decreased from 308.6 +/- 25.9 microm at baseline to 268.4 +/- 22.4 microm at month 3 (P = 0.0001). CRT was 365.8 +/- 84.9 and 254.9 +/- 95.1 microm at month 3 (P = 0.0002). The mean RPE lesion area was 6.0 +/- 3.0 mm(2) at baseline, which decreased to 5.0 +/- 3.1 mm(2) at month 3 (P = 0.115). The only significant correlation was identified between the lesion area and CRS. CONCLUSIONS: In ranibizumab therapy, the condition of the RPE lesion may be more relevant for visual function than the usual OCT parameters, retinal thickness.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.08-2017

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 65

Metadata

Authors
Kiss, C. G., Geitzenauer, W., Simader, C., Gregori, G., & Schmidt-Erfurth, U.
Venue
Investigative Opthalmology & Visual Science
Published
2009-05-01
Volume
50
Issue
5
Pages
2376
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2045832807
Cited by
65
References
3
FWCI
8.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Ranibizumab-Induced Changes in High-Resolution Optical Coherence Tomographic Retinal Morphology and Their Impact on Visual Function. https://app.cochat.ai/papers/10.1167/iovs.08-2017
The paper
Kiss, C. G., Geitzenauer, W., Simader, C., Gregori, G., & Schmidt-Erfurth, U. (2009). Evaluation of Ranibizumab-Induced Changes in High-Resolution Optical Coherence Tomographic Retinal Morphology and Their Impact on Visual Function. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.08-2017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.