CoChat

Comparison of the New Perimetric GATE Strategy with Conventional Full-Threshold and SITA Standard Strategies

Open access
Schiefer, Ulrich, Pascual, John P., Edmunds, Beth, Feudner, Elisabeth, Hoffmann, Esther M., Johnson, Chris A., Lagre`ze, Wolf A., Pfeiffer, Norbert, Sample, Pamela A., Staubach, Flemming, Weleber, Richard G., Vonthein, Reinhard, Krapp, Elke, Paetzold, Jens · 2009 · Investigative Opthalmology & Visual Science
Cited by 67

The DOI matches its Crossref record.

Abstract

PURPOSE: A new, fast-threshold strategy, German Adaptive Thresholding Estimation (GATE/GATE-i), is compared to the full-threshold (FT) staircase and the Swedish Interactive Thresholding Algorithm (SITA) Standard strategies. GATE-i is performed in the initial examination and GATE refers to the results in subsequent examinations. METHODS: Sixty subjects were recruited for participation in the study: 40 with manifest glaucoma, 10 with suspected glaucoma, and 10 with ocular hypertension. The subjects were evaluated by each threshold strategy on two separate sessions within 14 days in a randomized block design. RESULTS: SITA standard, GATE-i, and GATE thresholds were 1.2, 0.6, and 0.0 dB higher than FT. The SITA standard tended to have lower thresholds than those of FT, GATE-i, and GATE for the more positive thresholds, and also in the five seed locations. For FT, GATE-i, GATE, and SITA Standard, the standard deviations of thresholds between sessions were, respectively, 3.9, 4.5, 4.2, and 3.1 dB, test-retest reliabilities (Spearman's rank correlations) were 0.84, 0.76, 0.79, and 0.71, test-retest agreements as measured by the 95% reference interval of differences were -7.69 to 7.69, -8.76 to 9.00, -8.40 to 8.56, and -7.01 to 7.44 dB, and examination durations were 9.0, 5.7, 4.7, and 5.6 minutes. The test duration for SITA Standard increased with increasing glaucomatous loss. CONCLUSIONS: The GATE algorithm achieves thresholds that are similar to those of FT and SITA Standard, with comparable accuracy, test-retest reliability, but with a shorter test duration than FT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.08-2229

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 67

Metadata

Authors
Schiefer, U., Pascual, J. P., Edmunds, B., Feudner, E., Hoffmann, E. M., Johnson, C. A., Lagre`ze, W. A., Pfeiffer, N., Sample, P. A., Staubach, F., Weleber, R. G., Vonthein, R., Krapp, E., & Paetzold, J.
Venue
Investigative Opthalmology & Visual Science
Published
2009-01-01
Volume
50
Issue
1
Pages
488
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2032280425
Cited by
67
References
0
FWCI
5.70
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of the New Perimetric GATE Strategy with Conventional Full-Threshold and SITA Standard Strategies. https://app.cochat.ai/papers/10.1167/iovs.08-2229
The paper
Schiefer, U., Pascual, J. P., Edmunds, B., Feudner, E., Hoffmann, E. M., Johnson, C. A., Lagre`ze, W. A., Pfeiffer, N., Sample, P. A., Staubach, F., Weleber, R. G., Vonthein, R., Krapp, E., & Paetzold, J. (2009). Comparison of the New Perimetric GATE Strategy with Conventional Full-Threshold and SITA Standard Strategies. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.08-2229

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.