Comparison of the New Perimetric GATE Strategy with Conventional Full-Threshold and SITA Standard Strategies
Open accessThe DOI matches its Crossref record.
Abstract
PURPOSE: A new, fast-threshold strategy, German Adaptive Thresholding Estimation (GATE/GATE-i), is compared to the full-threshold (FT) staircase and the Swedish Interactive Thresholding Algorithm (SITA) Standard strategies. GATE-i is performed in the initial examination and GATE refers to the results in subsequent examinations. METHODS: Sixty subjects were recruited for participation in the study: 40 with manifest glaucoma, 10 with suspected glaucoma, and 10 with ocular hypertension. The subjects were evaluated by each threshold strategy on two separate sessions within 14 days in a randomized block design. RESULTS: SITA standard, GATE-i, and GATE thresholds were 1.2, 0.6, and 0.0 dB higher than FT. The SITA standard tended to have lower thresholds than those of FT, GATE-i, and GATE for the more positive thresholds, and also in the five seed locations. For FT, GATE-i, GATE, and SITA Standard, the standard deviations of thresholds between sessions were, respectively, 3.9, 4.5, 4.2, and 3.1 dB, test-retest reliabilities (Spearman's rank correlations) were 0.84, 0.76, 0.79, and 0.71, test-retest agreements as measured by the 95% reference interval of differences were -7.69 to 7.69, -8.76 to 9.00, -8.40 to 8.56, and -7.01 to 7.44 dB, and examination durations were 9.0, 5.7, 4.7, and 5.6 minutes. The test duration for SITA Standard increased with increasing glaucomatous loss. CONCLUSIONS: The GATE algorithm achieves thresholds that are similar to those of FT and SITA Standard, with comparable accuracy, test-retest reliability, but with a shorter test duration than FT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical coherence tomography in multiple sclerosis: a systematic review and meta-analysis
Petzold, A., de Boer, J. F., Schippling, S., Vermersch, P., Kardon, R., Green, A., Calabresi, P. A., & Polman, C. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70168-x · Cited by 596
The investigation of acute optic neuritis: a review and proposed protocol
Petzold, A., Wattjes, M. P., Costello, F., Flores-Rivera, J., Fraser, C. L., Fujihara, K., Leavitt, J., Marignier, R., Paul, F., Schippling, S., et al. (2014) · Nature Reviews Neurology · doi:10.1038/nrneurol.2014.108 · Cited by 270
Weleber, R. G., Pennesi, M. E., Wilson, D. J., Kaushal, S., Erker, L. R., Jensen, L., McBride, M. T., Flotte, T. R., Humphries, M., Calcedo, R., et al. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2016.03.003 · Cited by 218
Self-citationSchatz, A., Röck, T., Naycheva, L., Willmann, G., Wilhelm, B., Peters, T., Bartz-Schmidt, K. U., Zrenner, E., Messias, A., & Gekeler, F. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6932 · Cited by 158
Pennesi, M. E., Yang, P., Birch, D. G., Weng, C. Y., Moore, A. T., Iannaccone, A., Comander, J. I., Jayasundera, T., Chulay, J., Chulay, J., et al. (2022) · Ophthalmology Retina · doi:10.1016/j.oret.2022.06.013 · Cited by 71
Metadata
- Authors
- Schiefer, U., Pascual, J. P., Edmunds, B., Feudner, E., Hoffmann, E. M., Johnson, C. A., Lagre`ze, W. A., Pfeiffer, N., Sample, P. A., Staubach, F., Weleber, R. G., Vonthein, R., Krapp, E., & Paetzold, J.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2009-01-01
- Volume
- 50
- Issue
- 1
- Pages
- 488
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2032280425
- Cited by
- 67
- References
- 0
- FWCI
- 5.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of the New Perimetric GATE Strategy with Conventional Full-Threshold and SITA Standard Strategies. https://app.cochat.ai/papers/10.1167/iovs.08-2229
- The paper
- Schiefer, U., Pascual, J. P., Edmunds, B., Feudner, E., Hoffmann, E. M., Johnson, C. A., Lagre`ze, W. A., Pfeiffer, N., Sample, P. A., Staubach, F., Weleber, R. G., Vonthein, R., Krapp, E., & Paetzold, J. (2009). Comparison of the New Perimetric GATE Strategy with Conventional Full-Threshold and SITA Standard Strategies. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.08-2229
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.