The DOI matches its Crossref record.
Detailed Ophthalmologic Evaluation of 43 Individuals with PAX6 Mutations
Abstract
PURPOSE: Heterozygous mutations of the PAX6 gene cause a variety of ocular malformations, the best known being aniridia (absence of the iris). Mutation analyses and detailed clinical evaluations were performed in 43 individuals with aniridia or closely related ocular anomalies, to investigate whether phenotype correlates with mutation type. METHODS: Case notes and medical records were reviewed and patients were reexamined when necessary. Denaturing high-performance liquid chromatography (DHPLC) analysis and sequencing of the PAX6 coding region was performed in individuals whose mutation was unknown. RESULTS: The most common PAX6 mutations identified were premature termination mutations, amino acid substitutions, and C-terminal extensions. Six novel mutations are reported. Mutations that inactivate one copy of the gene typically caused a severe phenotype including foveal hypoplasia, marked iris anomalies, and severe visual impairment. Missense mutations, all affecting invariant amino acids in the paired domain, caused milder phenotypes in this cohort, with a lower incidence of foveal hypoplasia and less severe visual loss. C-terminal extension mutations caused relatively severe anomalies and marked reduction in vision. Two C-terminal extension cases had a unilateral exudative retinopathy, resembling Coats' disease, which has not previously been reported in association with PAX6 mutation. CONCLUSIONS: PAX6 mutations cause panocular malformations that vary considerably in pattern and severity. In our cohort, iris hypoplasia, nystagmus, and foveal hypoplasia were most common, with cataracts, corneal anomalies, and high refractive errors also frequently observed. In this cohort, loss-of-function and C-terminal extension mutations were found to cause more severe phenotypes than missense mutations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Structural Grading of Foveal Hypoplasia Using Spectral-Domain Optical Coherence Tomography
Thomas, M. G., Kumar, A., Mohammad, S., Proudlock, F. A., Engle, E. C., Andrews, C., Chan, W.-M., Thomas, S., & Gottlob, I. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2011.01.028 · Cited by 427
Regulation of cerebral cortical neurogenesis by the Pax6 transcription factor
Manuel, M. N., Mi, D., Mason, J. O., & Price, D. J. (2015) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2015.00070 · Cited by 153
Congenital aniridia—A comprehensive review of clinical features and therapeutic approaches
Landsend, E. C. S., Lagali, N., & Utheim, T. P. (2021) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2021.02.011 · Cited by 122
Metadata
- Authors
- Hingorani, M., Williamson, K. A., Moore, A. T., & van Heyningen, V.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2009-06-01
- Volume
- 50
- Issue
- 6
- Pages
- 2581
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2027886945
- Cited by
- 192
- References
- 0
- FWCI
- 4.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detailed Ophthalmologic Evaluation of 43 Individuals with PAX6 Mutations. https://app.cochat.ai/papers/10.1167/iovs.08-2827
- The paper
- Hingorani, M., Williamson, K. A., Moore, A. T., & van Heyningen, V. (2009). Detailed Ophthalmologic Evaluation of 43 Individuals with PAX6 Mutations. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.08-2827
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.