PURPOSE: To determine the test-retest variability of the retinal sensitivity of the Nidek MP1 microperimeter in patients with macular disease. METHODS: In this prospective study, 50 patients were enrolled with a range of macular diseases. One examiner performed two consecutive microperimetry tests for all patients using the same test strategy. Test-retest variability for mean sensitivity (MS), mean deviation (MD), point-wise sensitivity (PWS), local defect classification (LDC), average sensitivity for the central macula (CMS, 16 loci inside 10 degrees ), paracentral macular sensitivity (PMS, 52 loci in the 10 to 20 degrees ring), and dense scotoma size (DSS) were analyzed by calculating the 95% coefficients of repeatability or percentage agreement. RESULTS: Mean (SD) age and visual acuity were 61 (15) years and 0.34 (0.32) logMAR, respectively. The mean difference in MS between tests 1 and 2 was +0.2 dB (SD, 0.9 dB; P = 0.127). The coefficients of repeatability for MS, MD, CMS, and PMS were 1.81, 2.56, 2.13, and 1.93 dB, respectively. The mean (SD) of coefficients of repeatability for PWS across all 68 loci was 5.56 (0.86) dB. Of all test loci in all patients 76% had perfect agreement in LDC, and 94% of patients had a change in DSS of four or fewer test loci. CONCLUSIONS: Test-retest variability was lowest for MS and highest for PWS. However, MS does not provide spatial information. The authors recommend the use of CMS and PMS for monitoring macular function and consider a change of greater than 2.56 and 2.31 dB (the upper limit of the 95% confidence interval of their coefficients of repeatability), respectively, to exceed test-retest variability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Effect of gene therapy on visual function in Leber’s congenital amaurosis
Bainbridge, J. W. B., Smith, A. J., Barker, S. S., Robbie, S., Henderson, R., Balaggan, K., Viswanathan, A., Holder, G. E., Stockman, A., Tyler, N., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0802268 · Cited by 1,924
Self-citation
Cited by
MacLaren, R. E., Groppe, M., Barnard, A. R., Cottriall, C. L., Tolmachova, T., Seymour, L., Clark, K. R., During, M. J., Cremers, F. P. M., Black, G. C. M., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(13)62117-0 · Cited by 796
Cukras, C., Wiley, H. E., Jeffrey, B. G., Sen, H. N., Turriff, A., Zeng, Y., Vijayasarathy, C., Marangoni, D., Ziccardi, L., Kjellstrom, S., et al. (2018) · Molecular Therapy · doi:10.1016/j.ymthe.2018.05.025 · Cited by 268
Fischer, M. D., Ochakovski, G. A., Beier, B., Seitz, I. P., Vaheb, Y., Kortuem, C., Reichel, F. F. L., Kuehlewein, L., Kahle, N. A., Peters, T., et al. (2019) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2019.3278 · Cited by 92
Changes in Retinal Sensitivity after Gene Therapy in Choroideremia
Fischer, M. D., Ochakovski, G. A., Beier, B., Seitz, I. P., Vaheb, Y., Kortuem, C., Reichel, F. F. L., Kuehlewein, L., Kahle, N. A., Peters, T., et al. (2020) · Retina · doi:10.1097/iae.0000000000002360 · Cited by 66
Metadata
- Authors
- Chen, F. K., Patel, P. J., Xing, W., Bunce, C., Egan, C., Tufail, A. T., Coffey, P. J., Rubin, G. S., & Da Cruz, L.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2009-07-01
- Volume
- 50
- Issue
- 7
- Pages
- 3464
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2044913417
- Cited by
- 146
- References
- 2
- FWCI
- 8.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Test–Retest Variability of Microperimetry Using the Nidek MP1 in Patients with Macular Disease. https://app.cochat.ai/papers/10.1167/iovs.08-2926
- The paper
- Chen, F. K., Patel, P. J., Xing, W., Bunce, C., Egan, C., Tufail, A. T., Coffey, P. J., Rubin, G. S., & Da Cruz, L. (2009). Test–Retest Variability of Microperimetry Using the Nidek MP1 in Patients with Macular Disease. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.08-2926
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.