CoChat

Differential Macular Morphology in Patients with RPE65-,CEP290-,GUCY2D-, and AIPL1-Related Leber Congenital Amaurosis

Open access
Pasadhika, Sirichai, Fishman, Gerald A., Stone, Edwin M., Lindeman, Martin, Zelkha, Ruth, Lopez, Irma, Koenekoop, Robert K., Shahidi, Mahnaz · 2010 · Investigative Opthalmology & Visual Science
Cited by 93

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

PURPOSE: To evaluate genotypic and macular morphologic correlations in patients with RPE65-, CEP290-, GUCY2D-, or AIPL1-related Leber congenital amaurosis (LCA) using spectral-domain optical coherence tomography (SD-OCT). METHODS: SD-OCT macular scans were performed in 21 patients, including 10 with RPE65, 7 with CEP290, 3 with GUCY2D, and 1 with AIPL1 mutations. An image processing software was used to manually draw segmentation lines by three observers. Lamellar structure was evaluated based on the number of retinal layers on segmented images. Total retinal thickness was measured at the central macular and perifoveal areas by using an automated algorithm. RESULTS: All three patients with GUCY2D mutations (age range, 20-53 years) retained six retinal layers with visible photoreceptor inner/outer segment juncture (PSJ). However, the preservation of lamellar structures did not parallel better visual acuity. Patients with other mutations had poorly defined PSJ and disorganized retinal lamellar structures, where only one to three retinal layers could be observed. Patients with CEP290 mutations trended to have retention of the outer nuclear layer at the fovea and macular thickening, especially at younger ages. In patients with RPE65 (age range, 20-71 years) and AIPL1 mutations (age, 22 years), macular thickness was markedly decreased. Disorganization of retinal lamellar structures in the RPE65 group trended toward a worsening with increasing age. CONCLUSIONS: Variations of macular microstructures were observed among LCA patients with different genotypes. Disorganization of retinal lamellar structure was generally age related. Preservation of retinal microanatomic structures may not be associated with better visual acuity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.09-3734

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 93

Metadata

Authors
Pasadhika, S., Fishman, G. A., Stone, E. M., Lindeman, M., Zelkha, R., Lopez, I., Koenekoop, R. K., & Shahidi, M.
Venue
Investigative Opthalmology & Visual Science
Published
2010-05-01
Volume
51
Issue
5
Pages
2608
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2028399549
Cited by
93
References
4
FWCI
3.19
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.