CoChat

Quantification of the Therapeutic Response of Intraretinal, Subretinal, and Subpigment Epithelial Compartments in Exudative AMD during Anti-VEGF Therapy

Golbaz, Isabelle, Ahlers, Christian, Stock, Geraldine, Schütze, Christopher, Schriefl, Sabine, Schlanitz, Ferdinand, Simader, Christian, Prünte, Christian, Schmidt-Erfurth, Ursula Margarethe · 2011 · Investigative Opthalmology & Visual Science
Cited by 77

The DOI matches its Crossref record.

Abstract

PURPOSE: To analyze the functional and morphologic effects of different ranibizumab treatment regimens on retinal and subretinal as well as sub-RPE compartments in neovascular age-related macular degeneration (nAMD) using spectral-domain optical coherence tomography (SD-OCT) and manual segmentation software. METHODS: Twenty-seven eyes of 27 patients with nAMD were examined over a 12-month period. Two treatment arms received either monthly or quarterly administered intravitreal ranibizumab. Intraretinal, subretinal, and sub-RPE volume equivalents were delineated using manual segmentation software over a defined series of B-scans obtained by SD-OCT. The mean area in pixels was calculated for each compartment at each time interval. RESULTS: SD-OCT and manual segmentation allowed for exact identification of intraretinal, subretinal and sub-RPE compartments and their responses to different treatment regimens. The loading dose demonstrated a corresponding treatment effect on all anatomic parameters. In contrast to the sub-RPE compartment, intraretinal fluid accumulation and subretinal fluid accumulation (SRFA) demonstrated an immediate response to ranibizumab therapy. The overall plasticity of the morphologic response declined over time. In general, SRFA demonstrated greater sensitivity for therapeutic effects and was more frequently associated with recurrent disease. CONCLUSIONS: An exact quantification of fluid in different anatomic compartments based on SD-OCT imaging, using appropriate segmentation software systems, may be useful to determine optimal treatment and retreatment parameters and explains the lack of correlation of best-corrected visual acuity and conventional OCT values.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.09-5018

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 77

Metadata

Authors
Golbaz, I., Ahlers, C., Stock, G., Schütze, C., Schriefl, S., Schlanitz, F., Simader, C., Prünte, C., & Schmidt-Erfurth, U. M.
Venue
Investigative Opthalmology & Visual Science
Published
2011-03-21
Volume
52
Issue
3
Pages
1599
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2066220002
Cited by
77
References
0
FWCI
5.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantification of the Therapeutic Response of Intraretinal, Subretinal, and Subpigment Epithelial Compartments in Exudative AMD during Anti-VEGF Therapy. https://app.cochat.ai/papers/10.1167/iovs.09-5018
The paper
Golbaz, I., Ahlers, C., Stock, G., Schütze, C., Schriefl, S., Schlanitz, F., Simader, C., Prünte, C., & Schmidt-Erfurth, U. M. (2011). Quantification of the Therapeutic Response of Intraretinal, Subretinal, and Subpigment Epithelial Compartments in Exudative AMD during Anti-VEGF Therapy. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.09-5018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.