CoChat

Complement Deposition and Microglial Activation in the Outer Retina in Light-Induced Retinopathy: Inhibition by a 5-HT1AAgonist

Open access
Collier, Robert J., Wang, Yu, Smith, Sherry S., Martin, Elizabeth, Ornberg, Richard, Rhoades, Kristina, Romano, Carmelo · 2011 · Investigative Opthalmology & Visual Science
Cited by 78

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

PURPOSE: Increasing evidence supports a role for complement in the pathogenesis of age-related macular degeneration (AMD). This study evaluated retinal microglia, T-lymphocytes, and complement deposition in a light-induced retinopathy model. The effect of a serotonin (5-hydroxytryptamine, 5-HT(1A)) agonist on these processes was investigated. METHODS: Rats were dark adapted for 24 hours before a 6-hour blue light exposure. Some animals were predosed subcutaneously with AL-8309A. Retinas were evaluated at different times after light exposure. Paraffin sections were stained with antibody for a microglial marker (Iba1), a T-lymphocyte marker (CD3), and complement components C1q, C3, factor B, factor H, and membrane attack complex (MAC). RESULTS: Light exposure resulted in substantial photoreceptor and RPE loss. Robust microglia activation and migration to the outer retina occurred rapidly. Substantial T-lymphocyte recruitment did not occur. Complement alternative pathway was strongly activated, resulting in the deposition of C3, factor B, factor H, and MAC in the area of photic lesions. Dosing with AL-8309A prevented retinal lesions and decreased microglia activation/recruitment and complement deposition in the outer retina. CONCLUSIONS: In blue light exposed retinas, microglia were activated and migrated toward the outer retina, whereas a T-lymphocyte response was minimal. The innate immune system was markedly activated, with substantial complement deposition in the outer retina after light exposure. This complement deposition was prevented by AL-8309A. This model may be useful in the evaluation of complement inhibitors and other neuroprotectants intended for ocular use. AL-8309 is under evaluation in the clinic and may be useful in the treatment of AMD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.10-6418

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

Metadata

Authors
Collier, R. J., Wang, Y., Smith, S. S., Martin, E., Ornberg, R., Rhoades, K., & Romano, C.
Venue
Investigative Opthalmology & Visual Science
Published
2011-10-11
Volume
52
Issue
11
Pages
8108
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2074165817
Cited by
78
References
18
FWCI
5.82
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.