CoChat

Effects of Ischemia–Reperfusion on Physiological Properties of Müller Glial Cells in the Porcine Retina

Wurm, Antje, Iandiev, Ianors, Uhlmann, Susann, Wiedemann, Peter, Reichenbach, Andreas, Bringmann, Andreas, Pannicke, Thomas · 2011 · Investigative Opthalmology & Visual Science
Cited by 49

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

PURPOSE: Transient retinal ischemia-reperfusion is associated with neuronal degeneration and activation of Müller glial cells. Reactive gliosis may impede the homeostatic functions of Müller cells. A viable animal model for human ischemic events should display similarities in eye size and retinal blood supply. Therefore, pigs were used in this investigation of physiological alterations in Müller cells after ischemia-reperfusion. METHODS: Transient retinal ischemia was induced in young adult pigs by high intraocular pressure in one eye for 1 hour. After 3 days of reperfusion, the retinal tissue and isolated Müller cells were used for osmotic swelling recordings, whole-cell patch-clamp experiments, Ca(2+) microfluorimetry, and immunohistochemistry. RESULTS: Müller cells in retinal slices from postischemic eyes but not control cells displayed a significant swelling of the somata when osmotic stress was applied by hypotonic extracellular solution. The amplitude of K(+) inward currents was significantly reduced (∼60% of the control value). This decrease was accompanied by a depolarization of the cell membrane. The number of Müller cell end feet displaying a Ca(2+) increase after application of adenosine 5'-triphosphate was increased in the ischemic retina. Moreover, reactive Müller cell gliosis was characterized by an (increased) expression of vimentin, glial fibrillary acidic protein, the phosphorylated mitogen-activated protein kinases extracellular signal-related kinase (ERK) 1 and 2, and the transcription factor c-fos. CONCLUSIONS: The alterations of reactive Müller cells after transient ischemia of the pig eye were similar to those found in rat and rabbit models, demonstrating that the porcine retina is a suitable model for the investigation of ischemic injury.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.10-6901

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Wurm, A., Iandiev, I., Uhlmann, S., Wiedemann, P., Reichenbach, A., Bringmann, A., & Pannicke, T.
Venue
Investigative Opthalmology & Visual Science
Published
2011-05-18
Volume
52
Issue
6
Pages
3360
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2057871269
Cited by
49
References
1
FWCI
4.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.