The DOI matches its Crossref record.
Anterior and Posterior Optic Nerve Head Blood Flow in Nonhuman Primate Experimental Glaucoma Model Measured by Laser Speckle Imaging Technique and Microsphere Method
Open accessAbstract
PURPOSE: To characterize optic nerve head (ONH) blood flow (BF) changes in nonhuman primate experimental glaucoma (EG) using laser speckle flowgraphy (LSFG) and the microsphere method and to evaluate the correlation between the two methods. METHODS: EG was induced in one eye each of 9 rhesus macaques by laser treatment to the trabecular meshwork. Prior to lasering and following onset of intraocular pressure (IOP) elevation, retinal never fiber layer thickness (RNFLT) and ONH BF were measured biweekly by spectral-domain optical coherence tomography and LSFG, respectively, until RNFLT loss was approximately 40% in the EG eye. Final BF was measured by LSFG and by the microsphere method in the anterior ONH (MS-BF(ANT)), posterior ONH (MS-BF(POST)), and peripapillary retina (MS-BF(PP)). RESULTS: Baseline RNFLT and LSFG-BF showed no difference between the two eyes (P = 0.69 and P = 0.43, respectively, paired t-test). Mean (± SD) IOP was 30 ± 6 mm Hg in EG eyes and 13 ± 2 mm Hg in control eyes (P < 0.001). EG eye RNFLT and LSFG-BF were reduced by 42 ± 16% (P < 0.0001) and 22 ± 13% (P = 0.003), respectively, at the final time point. EG eye MS-BF(ANT), MS-BF(POST), and MS-BF(PP) were reduced by 41 ± 17% (P < 0.001), 22 ± 34% (P = 0.06), and 30 ± 12% (P = 0.001), respectively, compared with the control eyes. Interocular ONH LSFG-BF differences significantly correlated to that measured by the microsphere method (R(2) = 0.87, P < 0.001). CONCLUSIONS: Chronic IOP elevation causes significant ONH BF decreases in the EG model. The high correlation between the BF reduction measured by LSFG and the microsphere method provides evidence that the LSFG is capable of assaying BF for a critical deep ONH region.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laser Speckle Contrast Imaging: Theory, Instrumentation and Applications
Senarathna, J., Rege, A., Li, N., & Thakor, N. V. (2013) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2013.2243140 · Cited by 269
Optic nerve head biomechanics in aging and disease
Downs, J. C. (2015) · Experimental Eye Research · doi:10.1016/j.exer.2015.02.011 · Cited by 139
Metadata
- Authors
- Wang, L., Cull, G. A., Piper, C., Burgoyne, C. F., & Fortune, B.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2012-12-17
- Volume
- 53
- Issue
- 13
- Pages
- 8303
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2032930138
- Cited by
- 164
- References
- 0
- FWCI
- 9.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.