The DOI matches its Crossref record.
Collagen Cross-Linking Using Rose Bengal and Green Light to Increase Corneal Stiffness
Open accessAbstract
PURPOSE: Photochemical cross-linking of corneal collagen is an evolving treatment for keratoconus and other ectatic disorders. We evaluated collagen cross-linking by rose bengal plus green light (RGX) in rabbit eyes and investigated factors important for clinical application. METHODS: Rose bengal (RB, 0.1%) was applied to deepithelialized corneas of enucleated rabbit eyes for 2 minutes. The diffusion distance of RB into the stroma was measured by fluorescence microscopy on frozen sections. RB-stained corneas were exposed to green (532-nm) light for 3.3 to 9.9 minutes (50-150 J/cm(2)). Changes in the absorption spectrum during the irradiation were recorded. Corneal stiffness was measured by uniaxial tensiometry. The spatial distribution of the stromal elastic modulus was assessed by Brillouin microscopy. Viable keratocytes were counted on H&E-stained sections 24 hours posttreatment. RESULTS: RB penetrated approximately 100 μm into the corneal stroma and absorbed >90% of the incident green light. RGX (150 J/cm(2)) increased stromal stiffness by 3.8-fold. The elastic modulus increased in the anterior approximately 120 μm of stroma. RB was partially photobleached during the 2-minute irradiation, but reapplication of RB blocked light transmission by >70%. Spectral measurements suggested that RGX initiated cross-linking by an oxygen-dependent mechanism. RGX did not decrease keratocyte viability. CONCLUSIONS: RGX significantly increases cornea stiffness in a rapid treatment (≅12 minutes total time), does not cause toxicity to keratocytes and may be used to stiffen corneas thinner than 400 μm. Thus, RGX may provide an attractive approach to inhibit progression of keratoconus and other ectatic disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Corneal Collagen Crosslinking: A Systematic Review
Sorkin, N., & Varssano, D. (2014) · Ophthalmologica · doi:10.1159/000357979 · Cited by 1,918
The Collagen Suprafamily: From Biosynthesis to Advanced Biomaterial Development
Sorushanova, A., Delgado, L. M., Wu, Z., Shologu, N., Kshirsagar, A., Raghunath, R., Mullen, A. M., Bayon, Y., Pandit, A., Raghunath, M., et al. (2019) · Advanced Materials · doi:10.1002/adma.201801651 · Cited by 1,151
Risk Factors for Progression to Penetrating Keratoplasty in Patients With Keratoconus
Reeves, S. W., Stinnett, S., Adelman, R. A., & Afshari, N. A. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.05.029 · Cited by 290
Delgado, L. M., Bayon, Y., Pandit, A., & Zeugolis, D. I. (2015) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2014.0290 · Cited by 272
Metadata
- Authors
- Cherfan, D., Verter, E. E., Melki, S., Gisel, T. E., Doyle, F. J., Scarcelli, G., Yun, S. H., Redmond, R. W., & Kochevar, I. E.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2013-05-13
- Volume
- 54
- Issue
- 5
- Pages
- 3426
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2156553577
- Cited by
- 184
- References
- 0
- FWCI
- 9.74
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Collagen Cross-Linking Using Rose Bengal and Green Light to Increase Corneal Stiffness. https://app.cochat.ai/papers/10.1167/iovs.12-11509
- The paper
- Cherfan, D., Verter, E. E., Melki, S., Gisel, T. E., Doyle, F. J., Scarcelli, G., Yun, S. H., Redmond, R. W., & Kochevar, I. E. (2013). Collagen Cross-Linking Using Rose Bengal and Green Light to Increase Corneal Stiffness. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.12-11509
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.