CoChat

Dose-Ranging Evaluation of Intravitreal siRNA PF-04523655 for Diabetic Macular Edema (the DEGAS Study)

Nguyen, Quan Dong, Schachar, Ronald A., Nduaka, Chudy I., Sperling, Marvin, Basile, Anthony S., Klamerus, Karen J., Chi-Burris, Katherine, Yan, Eric, Paggiarino, Dario A., Rosenblatt, Irit, Aitchison, Roger, Erlich, Shai S. · 2012 · Investigative Opthalmology & Visual Science
Cited by 100

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

PURPOSE: To evaluate the safety and efficacy of three doses of PF-04523655, a 19-nucleotide methylated double stranded siRNA targeting the RTP801 gene, for the treatment of diabetic macular edema (DME) compared to focal/grid laser photocoagulation. METHODS: This multicenter, prospective, masked, randomized, active-controlled, phase 2 interventional clinical trial enrolled 184 DME patients with best corrected visual acuity (BCVA) of 20/40 to 20/320 inclusive in the study eye. Patients were randomly assigned to 0.4-mg, 1-mg, 3-mg PF-04523655 intravitreal injections or laser. The main outcome measure was the change in BCVA from baseline to month 12. RESULTS: All doses of PF-04523655 improved BCVA from baseline through month 12. At month 12, the PF-04523655 3-mg group showed a trend for greater improvement in BCVA from baseline than laser (respectively 5.77 vs. 2.39 letters; P = 0.08; 2-sided α = 0.10). The study was terminated early at month 12 based on predetermined futility criteria for efficacy and discontinuation rates. PF-04523655 was generally safe and well-tolerated, with few adverse events considered treatment-related. By month 12, the discontinuation rates in the PF-04523655 groups were higher than the laser group and were inversely related to dose levels. CONCLUSIONS: PF-04523655 showed a dose-related tendency for improvement in BCVA in DME patients. Studies of higher doses are planned to determine the optimal efficacious dose of PF-04523655. PF-04523655 may offer a new mode of therapeutic action in the management of DME. (ClinicalTrials.gov number, NCT00701181.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.12-9961

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 100

Metadata

Authors
Nguyen, Q. D., Schachar, R. A., Nduaka, C. I., Sperling, M., Basile, A. S., Klamerus, K. J., Chi-Burris, K., Yan, E., Paggiarino, D. A., Rosenblatt, I., Aitchison, R., & Erlich, S. S.
Venue
Investigative Opthalmology & Visual Science
Published
2012-11-15
Volume
53
Issue
12
Pages
7666
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W1983275470
Cited by
100
References
3
FWCI
9.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.