Cited by 78Neuroscience and Neural EngineeringRetinal Development and DisordersPain Management and Treatment

Factors Affecting Perceptual Thresholds in a Suprachoroidal Retinal Prosthesis

Shivdasani, Mohit N., Sinclair, Nicholas C., Dimitrov, Peter N., Varsamidis, Mary, Ayton, Lauren N., Luu, Chi D., Perera, Thushara, McDermott, Hugh J. +1 more·2014·Investigative Opthalmology & Visual Science

Abstract

PURPOSE: The suprachoroidal location for a retinal prosthesis provides advantages over other locations in terms of a simplified surgical procedure and a potentially more stable electrode-neural interface. The aim of this study was to assess the factors affecting perceptual thresholds, and to optimize stimulus parameters to achieve the lowest thresholds in patients implanted with a suprachoroidal retinal prosthesis. METHODS: Three patients with profound vision loss from retinitis pigmentosa were implanted with a suprachoroidal array. Perceptual thresholds measured on individual electrodes were analyzed as a function of stimulus (return configuration, pulse polarity, pulse width, interphase gap, and rate), electrode (area and number of ganged electrodes), and clinical (retinal thickness and electrode-retina distance) parameters. RESULTS: A total of 92.8% of 904 measurements made up to 680 days post implantation yielded thresholds (range, 44-436 nanocoulombs [nC]) below the safe charge limit. Thresholds were found to vary between individuals and to depend significantly on electrode-retina distance, negligibly on retinal thickness, and not on electrode area or the number of ganged electrodes. Lowest thresholds were achieved when using a monopolar return, anodic-first polarity, short pulse widths (100 μs) combined with long interphase gaps (500 μs), and high stimulation rates (≥400 pulses per second [pps]). CONCLUSIONS: With suprachoroidal stimulation, anodic-first pulses with a monopolar return are most efficacious. To enable high rates, an appropriate combination of pulse width and interphase gap must be chosen to ensure low thresholds and electrode voltages. Electrode-retina distance needs to be monitored carefully owing to its influence on thresholds. These results inform implantable stimulator specifications for a suprachoroidal retinal prosthesis. (ClinicalTrials.gov number, NCT01603576.).

Integrity signals

Registry

Crossref · 10.1167/iovs.14-14396

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A common approach is to use bipolar stimulation through two close electrodes, as shown in retinal, optic nerve, and thalamic prostheses.

    “A common approach is to use bipolar stimulation through two close electrodes, as shown in retinal [36,143,144], optic nerve [75], and thalamic prostheses [81].”

The citation lists haven’t been fetched yet

References 73 · Cited by 78

Authors
Shivdasani, M. N., Sinclair, N. C., Dimitrov, P. N., Varsamidis, M., Ayton, L. N., Luu, C. D., Perera, T., McDermott, H. J., & Blamey, P. J.
Affiliations
  • Bionics Institute (AU)
  • The University of Melbourne (AU)
Corresponding author
Shivdasani, Mohit N.
Venue
Investigative Opthalmology & Visual Science
Published
2014-10-14
Volume
55
Issue
10
Pages
6467
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W1978102660
Cited by
78
References
73
Citations by year
2026: 2 · 2025: 1 · 2024: 3 · 2023: 3 · 2022: 8 · 2021: 6 · 2020: 5 · 2019: 6 · 2018: 8 · 2017: 8 · 2016: 21 · 2015: 5 · 2014: 2
FWCI
5.48
Type
journal article
Language
en
Open access
closed
Locations
  • Investigative Ophthalmology & Visual Science (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Retinal Development and Disorders
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
Keywords
perceptual thresholds, retinitis pigmentosa, pulse polarity, pulse duration, stimulation rate, retinal thickness, electrode voltage, implantable stimulator
MeSH terms
Adult, Electric Stimulation, Evoked Potentials, Visual, Female, Humans, Male, Microelectrodes, Middle Aged, Prosthesis Design, Retina, Retinitis Pigmentosa, Visual Cortex, Visual Perception, Treatment Outcome, Young Adult, Visual Prosthesis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review