Scleral Thinning After Repeated Intravitreal Injections of Antivascular Endothelial Growth Factor Agents in the Same Quadrant
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PURPOSE: We assessed the effects of intravitreal anti-vascular endothelial growth factor (anti-VEGF) therapy on scleral architecture using spectral domain anterior segment optical coherence tomography (OCT). METHODS: A total of 35 eyes of 35 patients treated with at least 30 intravitreal injections in one eye in the inferotemporal quadrant with ranibizumab or aflibercept and 10 or less intravitreal injections in the fellow eye attending the intravitreal injection clinic were included. Enhanced depth imaging anterior segment OCT was used to measure scleral thickness. For each eye the sclera was measured in four quadrants at 3 mm from the limbus. In addition axial eye length was measured in all subjects using partial coherence interferometry. RESULTS: The mean number of intravitreal injections was 42 (range, 30-73) and 1.6 (range, 0-9) in the fellow eyes. In the study eyes with more than 30 injections the average scleral thickness in the inferotemporal quadrant was 568.4 μm (SD ± 66 μm) and 590.6 μm (SD ± 75 μm) in the fellow eyes with 10 or less injections (P = 0.003). The mean average scleral thickness in the other three quadrants (inferonasal, superotemporal, and superonasal) was 536.6 μm in the study eyes (SD ± 100 μm) and 545.2 μm (SD ± 109 μm) in the fellow eyes (P = 0.22). There was a borderline association of the total number of injections with scleral thickness change in the inferotemporal quadrant (r = 0.3, P = 0.052). CONCLUSIONS: Intravitreal injections may lead to scleral changes when applied repeatedly in the same quadrant. Thus, alternating the injection site should be considered in patients requiring multiple intravitreal injections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brown, D. M., Michels, M., Kaiser, P. K., Heier, J. S., Sy, J. P., & Ianchulev, T. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2008.10.018 · Cited by 1,318
Cited by
Aflibercept for neovascular age-related macular degeneration
Sarwar, S., Clearfield, E., Soliman, M. K., Sadiq, M. A., Baldwin, A. J., Hanout, M., Agarwal, A., Sepah, Y. J., Do, D. V., & Nguyen, Q. D. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011346.pub2 · Cited by 142
Boyle, J., Vukicevic, M., Koklanis, K., Itsiopoulos, C., & Rees, G. (2018) · Psychology, Health & Medicine · doi:10.1080/13548506.2016.1274040 · Cited by 119
Xu, M., Fan, R., Fan, X., Shao, Y., & Li, X. (2022) · Drug Design, Development and Therapy · doi:10.2147/dddt.s383101 · Cited by 111
Metadata
- Authors
- Zinkernagel, M. S., Schorno, P., Ebneter, A., & Wolf, S.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2015-03-31
- Volume
- 56
- Issue
- 3
- Pages
- 1894
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2070890840
- Cited by
- 37
- References
- 1
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.