Abstract

PURPOSE: We determined the intraocular pharmacokinetic properties of intravitreally injected aflibercept (Eylea) in a rabbit model. METHODS: Aflibercept was injected intravitreally in 21 eyes from New Zealand White rabbits. The eyes were enucleated 1, 24, 48, 120, 216, 360, and 720 hours (1, 2, 5, 9, 15, and 30 days, respectively) after injection and immediately frozen at -80°C. The concentrations of aflibercept in the vitreous, aqueous humor, and retina/choroid were determined by performing an indirect enzyme-linked immunosorbent assay, and analyzed to understand the pharmacokinetic properties of the drug. RESULTS: The maximum concentration of aflibercept was observed 1, 48 (2 days), and 24 (1 day) hours after intravitreal administration in the vitreous, aqueous humor, and retina/choroid, respectively. The one-compartment model was selected as the final model for all three ocular tissues. In the vitreous, aqueous humor, and retina/choroid, the estimated half-lives of aflibercept were 94.1, 48.0, and 58.2 hours, and the estimated mean residence times (MRTs) were 135.8, 69.2, and 84.0 hours, respectively. The area under curve from time 0 to the end point (AUClast) was 135,810.6 hours × μg/mL for the vitreous, 13,889.7 hours × μg/mL for the aqueous humor, and 2453.1 hours × μg/g for the retina/choroid. CONCLUSIONS: In rabbits, the vitreous half-life of aflibercept is 94.1 hours (3.92 days). This is shorter than that of bevacizumab (6.99 days), and longer than that of ranibizumab (2.51 days) and VEGF-Trap (3.63 days).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.16-19204

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • VEGF-Trap: A VEGF blocker with potent antitumor effects

    Holash, J., Davis, S., Papadopoulos, N., Croll, S. D., Ho, L., Russell, M., Boland, P., Leidich, R., Hylton, D., Burova, E., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.172398299 · Cited by 1,691 · cited 1×

    “might result in differences in their intraocular PK properties.(1,3) Moreover, the commercially available VEGF Trap-Eye, Eylea, (which is widely used in clinical practice) passes through several manufacturing processes, which also might affect its intraocular PK properties.”
    Background

Cited by

See all 94

Metadata

Authors
Park, S. J., Choi, Y., Na, Y. M., Hong, H. K., Park, J. Y., Park, K. H., Chung, J. Y., & Woo, S. J.
Venue
Investigative Opthalmology & Visual Science
Published
2016-05-12
Volume
57
Issue
6
Pages
2612
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2369816396
Cited by
94
References
1
FWCI
6.67
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.