Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 297

The DOI matches its Crossref record.

A Novel Strategy for Quantifying Choriocapillaris Flow Voids Using Swept-Source OCT Angiography

Open access
Zhang, Qinqin, Zheng, Fang, Motulsky, Elie H., Gregori, Giovanni, Chu, Zhongdi, Chen, Chieh-Li, Li, Chunxia, de Sisternes, Luis, Durbin, Mary, Rosenfeld, Philip J., Wang, Ruikang K.·2018·Investigative Opthalmology & Visual Science

Abstract

Purpose: To achieve reproducible imaging of the choriocapillaris and associated flow voids using swept-source OCT angiography (SS-OCTA). Methods: Subjects were enrolled and SS-OCTA was performed using the 3 × 3 mm scan pattern. Blood flow was identified using the complex optical microangiography (OMAG) algorithm. The choriocapillaris was defined as a slab from the outer boundary of Bruch's membrane (BM) to approximately 20 μm below BM. Compensation for the shadowing effect caused by the RPE and BM complex on the choriocapillaris angiogram was achieved by using the structural information from the same slab. A thresholding method to calculate the percentage of flow voids from a region was developed based on a normal database. Results: Twenty normal subjects and 12 subjects with drusen were enrolled. SS-OCTA identified the choriocapillaris in normal subjects as a lobular plexus of capillaries in the central macula and the lobular arrangement became more evident toward the periphery. In all eyes, signal compensation resulted in fewer choriocapillaris flow voids with improved repeatability of measurements. The best repeatability for the measurement was achieved by using 1 standard deviation (SD) for the thresholding strategy. Conclusions: SS-OCTA can image the choriocapillaris in vivo, and the repeatability of flow void measurements is high in the presence of drusen. The ability to image the choriocapillaris and associated flow voids should prove useful in understanding disease onset, progression, and response to therapies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.17-22953

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 297

Metadata

Authors
Zhang, Q., Zheng, F., Motulsky, E. H., Gregori, G., Chu, Z., Chen, C.-L., Li, C., de Sisternes, L., Durbin, M., Rosenfeld, P. J., & Wang, R. K.
Venue
Investigative Opthalmology & Visual Science
Published
2018-01-22
Volume
59
Issue
1
Pages
203
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2784283772
Cited by
297
References
0
FWCI
23.94
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Novel Strategy for Quantifying Choriocapillaris Flow Voids Using Swept-Source OCT Angiography. https://app.cochat.ai/papers/10.1167/iovs.17-22953
The paper
Zhang, Q., Zheng, F., Motulsky, E. H., Gregori, G., Chu, Z., Chen, C.-L., Li, C., de Sisternes, L., Durbin, M., Rosenfeld, P. J., & Wang, R. K. (2018). A Novel Strategy for Quantifying Choriocapillaris Flow Voids Using Swept-Source OCT Angiography. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.17-22953

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.