CoChat

Automated Diagnosis and Grading of Diabetic Retinopathy Using Optical Coherence Tomography

Open access
Sandhu, Harpal Singh, Eltanboly, Ahmed, Shalaby, Ahmed, Keynton, Robert S., Schaal, Schlomit, El-Baz, Ayman · 2018 · Investigative Opthalmology & Visual Science

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Abstract

Purpose: We determine the feasibility and accuracy of a computer-assisted diagnostic (CAD) system to diagnose and grade nonproliferative diabetic retinopathy (NPDR) from optical coherence tomography (OCT) images. Methods: A cross-sectional, single-center study was done of type II diabetics who presented for routine screening and/or monitoring exams. Inclusion criteria were age 18 or older, diagnosis of diabetes mellitus type II, and clear media allowing for OCT imaging. Exclusion criteria were inability to image the macula, posterior staphylomas, proliferative diabetic retinopathy, and concurrent retinovascular disease. All patients underwent a full dilated eye exam and spectral-domain OCT of a 6 × 6 mm area of the macula in both eyes. These images then were analyzed by a novel CAD system that segments the retina into 12 layers; quantifies the reflectivity, curvature, and thickness of each layer; and ultimately uses this information to train a neural network that classifies images as either normal or having NPDR, and then further grades the level of retinopathy. A first dataset was tested by "leave-one-subject-out" (LOSO) methods and by 2- and 4-fold cross-validation. The system then was tested on a second, independent dataset. Results: Using LOSO experiments on a dataset of images from 80 patients, the proposed CAD system distinguished normal from NPDR subjects with 93.8% accuracy (sensitivity = 92.5%, specificity = 95%) and achieved 97.4% correct classification between subclinical and mild/moderate DR. When tested on an independent dataset of 40 patients, the proposed system distinguished between normal and NPDR subjects with 92.5% accuracy and between subclinical and mild/moderate NPDR with 95% accuracy. Conclusions: A CAD system for automated diagnosis of NPDR based on macular OCT images from type II diabetics is feasible, reliable, and accurate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.17-23677

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 The framework of the proposed approach illustrating the main steps of the system.
Figure 1 The framework of the proposed approach illustrating the main steps of the system.CC BY · PubMed Central
Figure 2 Reflectivity (a), curvature (b), and thickness (c) features are illustrated. (a) The red and blue rectangles illustrate the reflectivity feature obtained from two regions per scan, comprising the thickest portions of the retina on the nasal and temporal sides of the foveal peak. (b) The color map demonstrates how curvature values range from low, colored blue, meaning closest to a straight line, to high, colored red. (c) The yellow bars depict thickness as the distance between two corresponding points at upper and lower boundaries of a given retinal layer.
Figure 2 Reflectivity (a), curvature (b), and thickness (c) features are illustrated. (a) The red and blue rectangles illustrate the reflectivity feature obtained from two regions per scan, comprising the thickest portions of the retina on the nasal and temporal sides of the foveal peak. (b) The color map demonstrates how curvature values range from low, colored blue, meaning closest to a straight line, to high, colored red. (c) The yellow bars depict thickness as the distance between two corresponding points at upper and lower boundaries of a given retinal layer.CC BY · PubMed Central
Figure 3 Examples of OCT images in row (A) for normal (1), subclinical DR (2), and mild-moderate DR (3) cases. Results of automated segmentation are displayed in row (B) showing the detected 13 boundaries.
Figure 3 Examples of OCT images in row (A) for normal (1), subclinical DR (2), and mild-moderate DR (3) cases. Results of automated segmentation are displayed in row (B) showing the detected 13 boundaries.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

Metadata

Authors
Sandhu, H. S., Eltanboly, A., Shalaby, A., Keynton, R. S., Schaal, S., & El-Baz, A.
Affiliations
  • University of Louisville (US)
  • Department of Ophthalmology and Visual Sciences, University of Massachusetts Medical School, Worchester, Massachusetts, United States
Corresponding author
Sandhu, Harpal Singh
Venue
Investigative Opthalmology & Visual Science
Published
2018-06-25
Volume
59
Issue
7
Pages
3155
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2811243935
Cited by
44
References
33
Citations by year
2026: 2 · 2025: 1 · 2024: 6 · 2023: 3 · 2022: 15 · 2021: 5 · 2020: 4 · 2019: 6 · 2018: 2
FWCI
2.93
Type
journal article
Language
en
Open access
Locations
  • Investigative Ophthalmology & Visual Science (publishedVersion, public-domain)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • eScholarship@UMassChan (submittedVersion, cc-by)
Funders
Research to Prevent Blindness (RPB-1944)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
  • Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
  • Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
Keywords
non-proliferative diabetic retinopathy, computer-aided diagnosis, optical coherence tomography, retinal layer segmentation, neural network classification, retinopathy grading, type 2 diabetes, macular OCT, automated diagnosis
MeSH terms
Adolescent, Adult, Aged, Aged, 80 and over, Cross-Sectional Studies, Diabetes Mellitus, Type 2, Diabetic Retinopathy, Diagnosis, Computer-Assisted, Female, Humans, Male, Middle Aged, Sensitivity and Specificity, Reproducibility of Results, Tomography, Optical Coherence, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.