The DOI matches its Crossref record.
A NEW METHOD FOR MEASURING AIRWAY RESISTANCE IN MAN USING A BODY PLETHYSMOGRAPH: VALUES IN NORMAL SUBJECTS AND IN PATIENTS WITH RESPIRATORY DISEASE 1
Open accessAbstract
Satisfactory methods, utilizing measurements of transthoracic or transpulmonary pressure and airflow, are now available for determining "nonelastic" pulmonary resistance.However, the nonelastic pulmonary resistance has two components, tissue resistance and airway resistance, and no valid direct method is available for measuring either of these components separately in man.Since airway resistance is the ratio of alveolar pressure during flow to airflow, airway resistance alone could be measured if there were a method for determining alveolar pressure during flow.This report presents a new method for accomplishing this measurement, and gives data for airway re- sistance obtained in normal subjects and in patients with respiratory disease.Of previous attempts to measure airway re- sistance, one of the earliest was the painstaking study by Rohrer (1) who made anatomical measurements on the tracheobronchial tree of a human lung post mortem and calculated the cumulative resistance to airflow of the entire system using Poiseuille's law and turbulence theory.The first important experimental study of pulmonary resistance in the living animal was made by von Neergaard and Wirz who, in 1927 (2), analyzed intrapleural pressure into two major components, "dynamic" (which is essentially resistive) and "static" (which is predominantly elastic in nature).This approach made it possible to obtain values for total pulmonary resistance, though not for airway resistance alone.Bayliss and Robertson (3), reasoning that airway resistance, but not tissue resistance, would vary with the viscosity of the gases breathed, ventilated isolated animal lungs with gases of different density and viscosity;
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
DuBois, A. B., Botelho, S. Y., Bedell, G. N., Marshall, R., & Comroe, J. H. (1956) · Journal of Clinical Investigation · doi:10.1172/jci103281 · Cited by 1,308
Self-citationPredicting Survival in Idiopathic Pulmonary Fibrosis
KING, T. E., TOOZE, J. A., SCHWARZ, M. I., BROWN, K. R., & CHERNIACK, R. M. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.7.2003140 · Cited by 853
Acute Bronchial Asthma: Relations between Clinical and Physiologic Manifestations
McFadden, E. R., Kiser, R., & DeGroot, W. J. (1973) · New England Journal of Medicine · doi:10.1056/nejm197302012880501 · Cited by 485
Effects of Obesity on Respiratory Resistance
Zerah, F., Harf, A., Perlemuter, L., Lorino, H., Lorino, A.-M., & Atlan, G. (1993) · Chest · doi:10.1378/chest.103.5.1470 · Cited by 450
Orehek, J., Massari, J. P., Gayrard, P., Grimaud, C., & Charpin, J. (1976) · Journal of Clinical Investigation · doi:10.1172/jci108281 · Cited by 296
Metadata
- Authors
- DuBois, A. B., Botelho, S. Y., & Comroe, J. H.
- Venue
- Journal of Clinical Investigation
- Published
- 1956-03-01
- Volume
- 35
- Issue
- 3
- Pages
- 327-335
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2107052422
- Cited by
- 1,277
- References
- 0
- FWCI
- 16.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A NEW METHOD FOR MEASURING AIRWAY RESISTANCE IN MAN USING A BODY PLETHYSMOGRAPH: VALUES IN NORMAL SUBJECTS AND IN PATIENTS WITH RESPIRATORY DISEASE 1. https://app.cochat.ai/papers/10.1172/jci103282
- The paper
- DuBois, A. B., Botelho, S. Y., & Comroe, J. H. (1956). A NEW METHOD FOR MEASURING AIRWAY RESISTANCE IN MAN USING A BODY PLETHYSMOGRAPH: VALUES IN NORMAL SUBJECTS AND IN PATIENTS WITH RESPIRATORY DISEASE 1. Journal of Clinical Investigation. https://doi.org/10.1172/jci103282
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.