Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 202

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

RED CELL, PLASMA, AND BLOOD VOLUME IN HEALTHY WOMEN MEASURED BY RADIOCHROMIUM CELL-LABELING AND HEMATOCRIT*

Open access
Brown, E., Hopper, J., Hodges, J. L., Bradley, B., Wennesland, R., Yamauchi, H.·1962·Journal of Clinical Investigation

Abstract

In a previous study of 201 healthy men (1), red cell volume (Vrbc) was measured by a modification of Sterling and Gray's radiochromium method (2), and whole blood and plasma volumes (Vwb and Vpl) were derived from venous he- miatocrits.The influence of factors other than body size on the variance of the data was studied, and standards for predicting normal volumes were derived.The present report describes a similar examination of 101 women. SUBJECTS AND METHODSThe women, all of whom volunteered for study, were actively employed as housewives, laboratory personnel, nurses, or office workers, and most were white (Table I).None were taking medications regularly or were subject to dietary control other than mild voluntary caloric restriction, and none were pregnant.Although some engaged in sports regularly, none were trained athletes.All had been living at sea level for at least a year.Cases of gross clinical obesity were not included.No subject was a regular blood donor, and none had given blood within 10 weeks.Health screening tech- niques included a medical history, physical examination, chest X-ray, and urinalysis.A hematocrit below 37 per cent, the limit of normal as defined by Wintrobe (3), caused exclusion of only one volunteer.In no subject was the arterial blood pressure over 140 mm Hg systolic or 90 mm Hg diastolic.The method' of labeling the autologous cells with NaCr5O4 and of determining their volume of distri- bution (VCr"1) was as described in the study on men (1, 4).Tests were performed before breakfast or, rarely, in the afternoon when lunch had been omitted.Subjects lay down for at least 30 minutes before the labeled cells were delivered and until sampling was completed no less than 35 minutes later.Precautions were taken to * Supported by U. S.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci104677

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 202

Metadata

Authors
Brown, E., Hopper, J., Hodges, J. L., Bradley, B., Wennesland, R., & Yamauchi, H.
Venue
Journal of Clinical Investigation
Published
1962-12-01
Volume
41
Issue
12
Pages
2182-2190
ISSN
0021-9738 (ISSN-L)
OpenAlex
W2096271605
Cited by
202
References
1
FWCI
4.36
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: RED CELL, PLASMA, AND BLOOD VOLUME IN HEALTHY WOMEN MEASURED BY RADIOCHROMIUM CELL-LABELING AND HEMATOCRIT*. https://app.cochat.ai/papers/10.1172/jci104677
The paper
Brown, E., Hopper, J., Hodges, J. L., Bradley, B., Wennesland, R., & Yamauchi, H. (1962). RED CELL, PLASMA, AND BLOOD VOLUME IN HEALTHY WOMEN MEASURED BY RADIOCHROMIUM CELL-LABELING AND HEMATOCRIT*. Journal of Clinical Investigation. https://doi.org/10.1172/jci104677

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.