Total Respiratory Inertance and Its Gas and Tissue Components in Normal and Obese Men *
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Total respiratory inertance may be defined as that component of the total impedance to breathing that relates to acceleration of respiratory gas and of all tissue elements (lungs, rib cage, diaphragm, and abdominal contents) that move during respiration. It is expressed in units of pressure required to overcome this inertial component of the total impedance and produce air flow acceleration of 1 L per second per second. Thus its units are centimeters H2O per liter per second2. Intuitively, one would suspect that the inertance of the chest and the abdomen should be increased in severely obese subjects. In investigations of total respiratory mechanics in excessively obese persons, we made measurements of total respiratory inertance. In addition, we attempted to separate the total respiratory inertance into its gas and tissue (including lung tissue, chest wall, and abdominal) components in three normal and three excessively obese subjects. These data form the substance of this report. Inertance data on the normal human respiratory system were first published by DuBois, Brody, Lewis, and Burgess (1) in 1956. These authors, assuming that the respiratory system behaves mechanically as a simple or lumped physical system, determined the total compliance and the natural frequency of the respiratory system. They then calculated the total inertance of the respiratory system by using the simple physical relationship by which the natural frequency of a system may be predicted if its elastic and inertial characteristics are known: fn = 1/274 1/jI *C, where fn
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Partitioning of respiratory flow resistance in man
Ferris, B. G., Mead, J., & Opie, L. H. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.4.653 · Cited by 448
Cited by
Effects of Obesity on Respiratory Function
Ray, C. S., Sue, D. Y., Bray, G., Hansen, J. E., & Wasserman, K. (1983) · American Review of Respiratory Disease · doi:10.1164/arrd.1983.128.3.501 · Cited by 558
Pulmonary mechanics by spectral analysis of forced random noise.
Michaelson, E. D., Grassman, E. D., & Peters, W. R. (1975) · Journal of Clinical Investigation · doi:10.1172/jci108198 · Cited by 410
The Total Work of Breathing in Normal and Obese Men*
Sharp, J. T., Henry, J. P., Sweany, S. K., Meadows, W. R., & Pietras, R. J. (1964) · Journal of Clinical Investigation · doi:10.1172/jci104957 · Cited by 340
Self-citationCurrent concepts in the pathogenesis of the obesity-hypoventilation syndrome
Rochester, D. F., & Enson, Y. (1974) · The American Journal of Medicine · doi:10.1016/0002-9343(74)90135-1 · Cited by 295
Expiratory flow limitation and intrinsic positive end-expiratory pressure in obesity
Pankow, W., Podszus, T., Gutheil, T., Penzel, T., Peter, J.-H., & Von Wichert, P. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.4.1236 · Cited by 240
“Because a major contribution of inertance to total respiratory system impedance was observed only at high breathing frequencies (27), it is unlikely that this mechanism affected the estimation of PEEPi during tidal breathing in our subjects.”
BackgroundPostural changes in lung volumes and respiratory resistance in subjects with obesity
Watson, R. A., & Pride, N. B. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00430.2004 · Cited by 211
“A few earlier studies have found an increase in airflow resistance (34, 40, 41) and in SRrs (40, 41) in obesity, but it is not possible from the way these results were presented to determine whether the increase was solely due to the reduced VL.”
ResultOscillation Mechanics of the Respiratory System
Peslin, R., & Fredberg, J. J. (1986) · Comprehensive Physiology · doi:10.1002/cphy.cp030311 · Cited by 181
Effect of obesity on respiratory mechanics during rest and exercise in COPD
Ora, J., Laveneziana, P., Wadell, K., Preston, M., Webb, K. A., & O'Donnell, D. E. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01131.2010 · Cited by 101
“The decreased EELV likely reflects the decreased chest wall and lung compliance known to be associated with obesity (27, 36, 37, 40).”
BackgroundEffect of obesity on constant workrate exercise in hyperinflated men with COPD
Laviolette, L., Sava, F., O'Donnell, D. E., Webb, K. A., Hamilton, A. L., Kesten, S., & Maltais, F. (2010) · BMC Pulmonary Medicine · doi:10.1186/1471-2466-10-33 · Cited by 43
“On one hand, obesity is associated with an increased work of breathing [9], increased breathing resistive load [10] and worse exertional dyspnea [11]; combined with COPD, these factors would likely increase demands on an already stressed respiratory system and further reduce exercise tolerance.”
Background
Metadata
- Authors
- Sharp, J. T., Henry, J. P., Sweany, S. K., Meadows, W. R., & Pietras, R. J.
- Venue
- Journal of Clinical Investigation
- Published
- 1964-03-01
- Volume
- 43
- Issue
- 3
- Pages
- 503-509
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2135146703
- Cited by
- 68
- References
- 1
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.