The Mechanism of Bicarbonate Reabsorption in the Proximal and Distal Tubules of the Kidney*

Open access
Rector, Floyd C., Carter, Norman W., Seldin, Donald W.·1965·Journal of Clinical Investigation

Abstract

Considerable evidence (1-6) has been adduced to support the hypothesis that the reabsorption of filtered HC03 by the kidney is mediated by a single mechanism, operafive in both the proximal and distal portions of the nephron, which involves the secretion of cellular H hi exchange for luminal Na. The secreted H reacts with filtered HCO3 to form I-I CO3, which then decomposes to CO2 and H O. Difficulties arise, however, when the details of the process are examined. In the steady state, the rate at which the H2CO3 is removed from the luminal fluid must equal the rate at which H is secreted. Walser and Mudge (7) have estimated that for the uncatalyzed dehydration of H2C03 to account for the observed rates of HCO3 reabsorption, the steady-state concentration of H2C03 in luminal fluid must be at least tenfold greater than the concentration that would exist were H2C03 in equilibrium with the CO2 tension of luminal fluid and plasma. As a result of the excess H2CO3, the steady-state pH would be approximately 1 pH U lower than would be predicted from the luminal concentration of HCO3 and the CO2 tension of plasma, assuming complete equilibration of luminal H2C03 with plasma CO2. A marked disequilibrium pH1 would exist. Two lines of evidence have been advanced to support the presence of a disequilibrium pH in the proximal tubule. Rector and Carter (8) perfused single proximal tubules with NaHCO3 and estimated the steady-state intraluminal pH from the change in color of various acidbase indicators. The pH was found to be about 1.5 U lower than the predicted equilibrium pH. However, since the color change could result from loss of dyes by either reabsorption or binding to cell proteins, the validity of these results may be questioned. Bank and Aynedjian (9) measured intratubular pH by aspirating tubular fluid into quinhydrone microelectrodes and comparing the readings while the electrode was still in the tubular lumen with the values obtained when the fluid was removed from the tubule and permitted to reach equilibrium. With this technique, they found the intratubular pH to be 2.0 to 2.5 pH

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci105142

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 279

Metadata

Authors
Rector, F. C., Carter, N. W., & Seldin, D. W.
Venue
Journal of Clinical Investigation
Published
1965-02-01
Volume
44
Issue
2
Pages
278-290
ISSN
0021-9738 (ISSN-L)
OpenAlex
W2071325348
Cited by
279
References
4
FWCI
12.26
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Mechanism of Bicarbonate Reabsorption in the Proximal and Distal Tubules of the Kidney*. https://app.cochat.ai/papers/10.1172/jci105142
The paper
Rector, F. C., Carter, N. W., & Seldin, D. W. (1965). The Mechanism of Bicarbonate Reabsorption in the Proximal and Distal Tubules of the Kidney*. Journal of Clinical Investigation. https://doi.org/10.1172/jci105142

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.