The DOI matches its Crossref record.
Usefulness of chromic oxide as an internal standard for balance studies in formula-fed patients and for assessment of colonic function
Open accessAbstract
In 35 patients maintained solely on liquid formula diets, chromic oxide has been evaluated as an internal standard for balance studies that require stool collections. In 28 patients the excretion of chromic oxide was ideal: steady states were attained in which mean daily output was 90% (or more) of mean daily intake. In these patients corrections for fecal flow could validly be applied.In patients who excreted the marker ideally, the availability of chromic oxide balance data made possible the calculation of pool sizes and turnover rates of unexcreted intestinal content. These indexes bore little relationship to the usual clinical descriptions of bowel habits. In some patient who had daily bowel movements, pool sizes were very large and daily turnover was small, i.e., a large proportion of the colonic contents was not excreted for surprisingly long periods. It is critically important for investigators to recognize this possibility when carrying out balance studies for fecal constituents that may be altered by bacterial action within the gut lumen: for instance, in 6 patients a significant inverse correlation was found between daily fecal turnover and degradative losses of large amounts of dietary beta-sitosterol.7 of 35 patients failed to attain the ideal steady state of chromic oxide excretion. These patients would not have been singled out if an internal standard had not been used. In such patients balance studies that require analysis of fecal constituents must be interpreted with great caution, since the constituents in question may be handled in the same nonideal fashion as the internal standard.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Effect of dietary stearic acid on plasma cholesterol and lipoprotein levels
Bonanome, A., & Grundy, S. M. (1988) · New England Journal of Medicine · doi:10.1056/nejm198805123181905 · Cited by 915
A new method for studying gut transit times using radioopaque markers
Hinton, J. M., Lennard-Jones, J. E., & Young, A. C. (1969) · Gut · doi:10.1136/gut.10.10.842 · Cited by 835
Shepherd, J., Packard, C. J., Grundy, S. M., Yeshurun, D., Gotto, A. M., & Taunton, O. D. (1980) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)39842-4 · Cited by 357
PASSCLAIM1?Gut health and immunity
Cummings, J. H., Antoine, J.-M., Azpiroz, F., Bourdet-Sicard, R., Brandtzaeg, P., Calder, P. C., Gibson, G. R., Guarner, F., Isolauri, E., Pannemans, D., et al. (2004) · European Journal of Nutrition · doi:10.1007/s00394-004-1205-4 · Cited by 324
Effects of dietary cholesterol on the regulation of total body cholesterol in man
QUINTÃO, E., GRUNDY, S. M., & AHRENS, E. H. (1971) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)39534-1 · Cited by 245
Self-citation
Metadata
- Authors
- Davignon, J., Simmonds, W. J., & Ahrens, E. H.
- Venue
- Journal of Clinical Investigation
- Published
- 1968-01-01
- Volume
- 47
- Issue
- 1
- Pages
- 127-138
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2036295891
- Cited by
- 189
- References
- 0
- FWCI
- 20.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Usefulness of chromic oxide as an internal standard for balance studies in formula-fed patients and for assessment of colonic function. https://app.cochat.ai/papers/10.1172/jci105703
- The paper
- Davignon, J., Simmonds, W. J., & Ahrens, E. H. (1968). Usefulness of chromic oxide as an internal standard for balance studies in formula-fed patients and for assessment of colonic function. Journal of Clinical Investigation. https://doi.org/10.1172/jci105703
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.