The DOI matches its Crossref record.
Measurement of Fibrinopeptide A in Human Blood
Open accessAbstract
Since thrombin cleaves fibrinopeptides A (FPA) and B from the NH(2)-terminal end of the fibrinogen molecule, measurement of fibrinopeptide levels in plasma may provide a direct index of thrombin action. Recently a radioimmunoassay for FPA has been developed, and in the present paper, we describe the application of this assay to the measurement of FPA levels in clinical blood samples. Since fibrinogen cross-reacts with antibodies to FPA, dialysis was used to extract the peptide from plasma. In vitro generation of FPA was prevented by removing the fibrinogen from the plasma by precipitation with ethanol before dialysis. The processing technique permitted recovery of 75% of FPA added to blood in vitro. Evidence that the immunoreactivity measured in plasma is due to FPA was provided by the results of experiments in which two antisera to FPA with different specificities showed comparable results and addition of thrombin caused no change in immunoreactivity. In contrast, extracts of streptokinasetreated plasma showed a five-fold increase in activity when treated with thrombin and markedly different immunoreactivity with the two antisera. Plasma FPA levels in 30 normal men were below 2 ng/ml, with a mean of 0.5 ng/ml. FPA levels in 12 patients with reduced fibrinogen levels or reduced platelet counts or both ranged between 4 and 289 ng/ml. FPA levels in 13 patients with normal or elevated fibrinogen levels, including 6 patients with clinical evidence of venous thrombosis or pulmonary embolism or both, ranged between 5 and 23 ng/ml. FPA and fibrinogen degradation product levels did not correlate, and in several patients, elevated FPA levels were found in the presence of normal fibrinogen degradation product levels. After infusion of FPA-containing solutions in four normal individuals, FPA showed a disappearance rate from the plasma consistent with a t((1/2)) of 3-5 min. Heparin infusions in six patients with venous thrombosis or pulmonary embolism or both and elevated FPA levels were followed by a prompt decline in FPA level at a mean rate equivalent to a 3-5 min t((1/2)).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Weitz, J. I., Hudoba, M., Massel, D., Maraganore, J., & Hirsh, J. (1990) · Journal of Clinical Investigation · doi:10.1172/jci114723 · Cited by 1,123
DIC: which laboratory tests are most useful
Levi, M., & Meijers, J. C. (2011) · Blood Reviews · doi:10.1016/j.blre.2010.09.002 · Cited by 146
Metadata
- Authors
- Nossel, H. L., Yudelman, I., Canfield, R. E., Butler, V. P., Spanondis, K., Wilner, G. D., & Qureshi, G. D.
- Venue
- Journal of Clinical Investigation
- Published
- 1974-07-01
- Volume
- 54
- Issue
- 1
- Pages
- 43-53
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2159162837
- Cited by
- 531
- References
- 0
- FWCI
- 25.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of Fibrinopeptide A in Human Blood. https://app.cochat.ai/papers/10.1172/jci107749
- The paper
- Nossel, H. L., Yudelman, I., Canfield, R. E., Butler, V. P., Spanondis, K., Wilner, G. D., & Qureshi, G. D. (1974). Measurement of Fibrinopeptide A in Human Blood. Journal of Clinical Investigation. https://doi.org/10.1172/jci107749
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.