CoChat

Circulating 3,3', 5'-triiodothyronine (reverse T3) in the human newborn.

Open access
Chopra, I J, Sack, J, Fisher, D A · 1975 · Journal of Clinical Investigation
Cited by 123

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Serum concentrations of 3,3',5'-triiodothyronine (reverse T3 rT3), 3,3',5-triiodothyronine (T), and thyroxine (T4) were measured in cord blood and invenous blood samples obtained between 2 h and 30 days of postnatal life from healthy full-term newborn infants. The mean serum rT3 concentration of (mean plus or minus SE) 151 plus or minus 12 ng per 100 ml in 18 cord blood samples was significantly higher than the level (41 plus or minus 2 ng per 100 ml) in 27 normal adult sera; the corresponding mean serum T4 of 12.7 plus or minus 0.8 mug per 100 ml in cord blood also was significantly higher than that (8.6 plus or minus 1.9 mug per 100 ml) in 108 normal adults. By contrast, the mean serum T3 concentration in 15 cord blood samples, 24 plus or minus 3 mg per 100 ml, was significantly lower than the value of 126 plus or minus 3.2 ng per 100 ml measured in 108 normal adults. At 4 h of age the mean serum rT3 concentration (165 plus or minus 13 ng per 100 ml) in six newborns was 4ot significantly different from that in paired cord blood samples (194 plus or minus 25 ng per 100 ml); on the other hand, whenever, studied, the mean serum T3 and T4 levels were significantly higher at 4 h than at birth. The failure of serum rT3 concentrations to rise after delivery in response to the early neonatal thyrotropin (TSH) surge and at a time when serum T3 and T4 levels increase significantly prompted a study of the rT3 response to 10 IU of intramuscular TSH in three healthy adult subjects. Just as in the newborns, serum rT3 failed to rise appreciably in these subjects, even though serum T3 and T4 showed the expected increments. Serum rT3 concentrations in 1-4 day-old newborn infants did not differ significantly from values in the cord blood but were significantly lower in older neonates. The mean serum rT3 level in 5-7-day-old infants was higher than that in normal adults, but in 9-11 day and 20-30-day-old infants, mean rT3 values were statistically similar to the adult value. The mean serum T3 concentrations in neonates between 1-30 days old were either higher than or comparable to the values of normal adults. The mean serum T4 concentrations in neonates between birth and 30 days of age were significantly higher than the mean adult level. The mean serum rT3 to T4 ratios (rT3/T4) were elevated in 1-4-day-old neonates; the values in older neonates were similar to those in adults. These results suggest that (a) factors other than TSH are important modulators of serum rT3 in man; (b) high serum rT3 concentration in the newborn becomes comparable to that in the normal adult by 9-11 days of neonatal life.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci108030

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 123

Metadata

Authors
Chopra, I. J., Sack, J., & Fisher, D. A.
Venue
Journal of Clinical Investigation
Published
1975-06-01
Volume
55
Issue
6
Pages
1137-1141
ISSN
0021-9738 (ISSN-L)
OpenAlex
W2073094378
Cited by
123
References
1
FWCI
18.26
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.