Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,077

The DOI matches its Crossref record.

Hemodynamic determinants of the time-course of fall in canine left ventricular pressure.

Open access
Weiss, J L, Frederiksen, J W, Weisfeldt, M L·1976·Journal of Clinical Investigation

Abstract

The hemodynamic determinants of the time-course of fall in isovolumic left ventricular pressure were assessed in isolated canine left ventricular preparations. Pressure fall was studied in isovolumic beats or during prolonged isovolumic diastole after ejection. Pressure fall was studied in isovolumic relaxation for isovolumic and ejecting beats (r less than or equal to 0.98) and was therefore characterized by a time constant, T. Higher heart rates shortened T slightly from 52.6 +/- 4.5 ms at 110/min to 48.2 +/- 6.0 ms at 160/min (P less than 0.01, n = 8). Higher ventricular volumes under isovolumic conditions resulted in higher peak left ventricular pressure but no significant change in T. T did shorten from 67.1 +/- 5.0 ms in isovolumic beats to 45.8 +/- 2.9 ms in the ejecting beats (P less than 0.001, n = 14). In the ejecting beats, peak systolic pressure was lower, and end-systolic volume smaller. To differentiate the effects of systolic shortening during ejection from those of lower systolic pressure and smaller end-systolic volume, beats with large end-diastolic volumes were compared to beats with smaller end-diastolic volumes. The beats with smaller end-diastolic volumes exhibited less shortening but similar end-systolic volumes and peak systolic pressure. T again shortened to a greater extent in the beats with greater systolic shortening. Calcium chloride and acetylstrophanthidin resulted in no significant change in T, but norepinephrine, which accelerates active relaxation, resulted in a significant shortening of T (65.6 +/- 13.4 vs. 46.3 +/- 7.0 ms, P less than 0.02). During recovery from ischemia, T increased significantly from 59.3 +/- 9.6 to 76.8 +/- 13.1 ms when compared with the preischemic control beat (P less than 0.05). Thus, the present studies show that the time-course of isovolumic pressure fall subsequent to maximum negative dP/dt is exponential, independent of systolic stress and end-systolic fiber length, and minimally dependent on heart rate. T may be an index of the activity of the active cardiac relaxing system and appears dependent on systolic fiber shortening.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci108522

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 1,077

Metadata

Authors
Weiss, J. L., Frederiksen, J. W., & Weisfeldt, M. L.
Venue
Journal of Clinical Investigation
Published
1976-09-01
Volume
58
Issue
3
Pages
751-760
ISSN
0021-9738 (ISSN-L)
OpenAlex
W2091360003
Cited by
1,077
References
0
FWCI
5.52
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hemodynamic determinants of the time-course of fall in canine left ventricular pressure. https://app.cochat.ai/papers/10.1172/jci108522
The paper
Weiss, J. L., Frederiksen, J. W., & Weisfeldt, M. L. (1976). Hemodynamic determinants of the time-course of fall in canine left ventricular pressure. Journal of Clinical Investigation. https://doi.org/10.1172/jci108522

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.