Characterization of glycosylated hemoglobins. Relevance to monitoring of diabetic control and analysis of other proteins.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Boronate affinity chromatography and ion exchange chromatography were used to measure the levels of glycosylated hemoglobins in normal and diabetic hemolysates, as well as the distribution of glucose adducts on alpha-NH2-valine and epsilon-NH2-lysine residues. When analyzed by ion exchange chromatography on BioRex 70 resin, the Hb Alc peak comprised 4.4 +/- 0.6% of 15 normal hemolysates and 9.1 +/- 2.1% of 15 diabetic hemolysates. The "Hb Alc" was rechromatographed on GlycoGel B boronate affinity resin that binds vicinal hydroxyl groups of covalently linked sugars. Only 70 +/- 5% of the hemoglobin adhered to the resin. Analysis by the thiobarbituric acid colorimetric test confirmed that the affinity resin effectively separated glycosylated from nonglycosylated hemoglobin. When corrected for nonglycosylated contaminants, the mean level of Hb Alc in normal hemolysates was 2.9 +/- 0.4%, a value considerably lower than those previously reported. In addition to Hb Alc, 5.2 +/- 0.5% of the remaining hemoglobin (Hb Ao) was glycosylated. In diabetics, glycosylated Ao was increased in parallel with Hb Alc. After reduction with [3H]borohydride and acid hydrolysis, glycosylated amino acids were first purified on Affi-Gel boronate affinity resin and then analyzed by ion exchange chromatography. The glucose adducts on Hb Ao were distributed as follows: alpha-chain N-terminal valine, 14%; alpha-chain lysines, 40%; beta-chain lysines, 46%. This study has revealed several pitfalls in the analysis of nonenzymatically glycosylated proteins. Peaks isolated by ion exchange chromatography or electrophoresis are likely to be contaminated by nonglycosylated proteins. Furthermore, both the thiobarbituric acid test and [3H]borohydride reduction show variable reactivity depending upon the site of the ketoamine-linked glucose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of acute changes in blood glucose on HbA1c
Goldstein, D. E., Peth, S. B., England, J. D., Hess, R. L., & Costa, J. D. (1980) · Diabetes · doi:10.2337/diab.29.8.623 · Cited by 145
Cited by
Zatz, R., Dunn, B. R., Meyer, T. W., Anderson, S., Rennke, H. G., & Brenner, B. M. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112521 · Cited by 1,209
Nonenzymatic Glycosylation and the Pathogenesis of Diabetic Complications
BROWNLEE, M., VLASSARA, H., & CERAMI, A. (1984) · Annals of Internal Medicine · doi:10.7326/0003-4819-101-4-527 · Cited by 1,007
Approved IFCC reference method for the measurement of HbA1c in human blood
Jeppsson, J.-O., Kobold, U., Barr, J., Finke, A., Hoelzel, W., Hoshino, T., Miedema, K., Mosca, A., Mauri, P., Paroni, R., et al. (2002) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2002.016 · Cited by 655
Zatz, R., Meyer, T. W., Rennke, H. G., & Brenner, B. M. (1985) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.82.17.5963 · Cited by 526
Protein adducts: quantitative and qualitative aspects of their formation, analysis and applications
Törnqvist, M., Fred, C., Haglund, J., Helleberg, H., Paulsson, B., & Rydberg, P. (2002) · Journal of Chromatography B · doi:10.1016/s1570-0232(02)00172-1 · Cited by 332
Metadata
- Authors
- Garlick, R. L., Mazer, J. S., Higgins, P. J., & Bunn, H. F.
- Venue
- Journal of Clinical Investigation
- Published
- 1983-05-01
- Volume
- 71
- Issue
- 5
- Pages
- 1062-1072
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2073773619
- Cited by
- 103
- References
- 1
- FWCI
- 5.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.