Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 161

The DOI matches its Crossref record.

Isolation and characterization of a colonic autoantigen specifically recognized by colon tissue-bound immunoglobulin G from idiopathic ulcerative colitis.

Open access
Takahashi, F, Das, K M · 1985 · Journal of Clinical Investigation

Abstract

Patients with idiopathic ulcerative colitis (UC) have a colonbound antibody (CCA-IgG) that reacts with colon tissue extracts. We have partially characterized a colonic protein that is specifically recognized by CCA-IgG. CCA-IgG was eluted from operative colon specimens from 10 patients with UC. A colon tissue-bound IgG was similarly eluted from six patients with Crohn's colitis, two with ischemic colitis, and one with diverticulitis. Purified serum IgG from patients with Crohn's disease, from normal subjects and a patient with myeloma were also used as additional controls. For detection of antigen(s), tissue extracts were prepared from 26 specimens of colon (UC, 12; Crohn's disease, 6; normal, 4; other controls, 4), 8 specimens of human normal stomach, duodenum, ileum, and liver (2 each). Tissue extracts were also prepared from rats and mice, including germ-free rat colons and rat's fetal colons. Immunorecognition of CCA-IgG to the tissue extracts was examined by affinity-column chromatography and by transblot analysis. Tissue-extracted proteins were electrophoresed in SDS-polyacrylamide gel, transferred to nitrocellulose sheet, and probed with iodinated CCA-IgG, colonic IgG from other inflammatory bowel disease patients, UC serum IgG, and control serum IgG. Although many proteins were present in colon tissue extracts, 9 of 10 CCA-IgG consistently recognized a protein of 40 kD. None of the nine IgG preparations from colon specimens of patients with Crohn's colitis and other colonic inflammatory diseases reacted with the 40-kD protein. Five of six symptomatic UC serum IgG and none of eight control serum IgG reacted with the 40-kD protein. The 40-kD protein was present in all colon specimens and it appeared to be organ specific. It was absent in mouse and rat tissues, including colon. The 40-kD protein is not actin and nor a part of the Ig molecule. These results suggest that the 40-kD protein is a colonic "autoantigen" that may initiate a specific IgG antibody response in UC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci111963

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 161

Metadata

Authors
Takahashi, F., & Das, K. M.
Venue
Journal of Clinical Investigation
Published
1985-07-01
Volume
76
Issue
1
Pages
311-318
ISSN
0021-9738 (ISSN-L)
OpenAlex
W2037487805
Cited by
161
References
0
FWCI
3.40
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Isolation and characterization of a colonic autoantigen specifically recognized by colon tissue-bound immunoglobulin G from idiopathic ulcerative colitis. https://app.cochat.ai/papers/10.1172/jci111963
The paper
Takahashi, F., & Das, K. M. (1985). Isolation and characterization of a colonic autoantigen specifically recognized by colon tissue-bound immunoglobulin G from idiopathic ulcerative colitis. Journal of Clinical Investigation. https://doi.org/10.1172/jci111963

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.