The DOI matches its Crossref record.
Role of CD11/CD18 in shear rate-dependent leukocyte-endothelial cell interactions in cat mesenteric venules.
Open accessAbstract
In vivo microscopy was used to assess the relationships among shear rate (and shear stress), leukocyte rolling velocity, and leukocyte adherence in a cat mesentery preparation. Shear rate in individual venules and arterioles of 25-35 microns diameter were varied over a wide range by graded occlusion of an arterial loop. There was a linear decline in leukocyte rolling velocity (Vwbc) as red cell velocity (Vrbc) was reduced. The ratio Vwbc/Vrbc remained constant despite variations in shear stress from 5-25 dyn/cm2. A reduction in shear stress was associated with an increased leukocyte adherence, particularly when Vwbc was reduced below 50 microns/s. Reduction in wall shear rate below 500 s-1 in arterioles allowed 1-3 leukocytes to adhere per 100 microns length of vessel, while venules exposed to the same shear rates had 5-16 adherent leukocytes. In arterioles, leukocyte rolling was only observed at low shear rates. At shear rates less than 250 s-1 leukocyte rolling velocity was faster in arterioles than venules, and the ratio Vwbc/Vrbc for arterioles was 0.08 +/- 0.02, which was fourfold higher than the ratio obtained in venules at similar shear rates. Pretreatment with the CD18-specific antibody (mAb) IB4 increased leukocyte rolling velocity in venules by approximately 20 microns/s at red cell velocities below 2,000 microns/s. mAb IB4 largely prevented the leukocyte adherence to arterioles and venules, and increased the ratio Vwbc/Vrbc observed in venules at low shear elicit a CD18-dependent adhesive interaction between leukocytes and microvascular endothelium, and that differences in shear rates cannot explain the greater propensity for leukocyte rolling and adhesion in venules than arterioles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
α4 integrins mediate lymphocyte attachment and rolling under physiologic flow
Berlin, C., Bargatze, R. F., Campbell, J. J., von Andrian, U. H., Szabo, M. C., Hasslen, S. R., Nelson, R. D., Berg, E. L., Erlandsen, S. L., & Butcher, E. C. (1995) · Cell · doi:10.1016/0092-8674(95)90491-3 · Cited by 1,003
The microcirculation and inflammation: modulation of leukocyte-endothelial cell adhesion
Granger, D. N., & Kubes, P. (1994) · Journal of Leukocyte Biology · doi:10.1002/jlb.55.5.662 · Cited by 849
Self-citationEndothelial cell interactions with granulocytes: tethering and signaling molecules
Zimmerman, G. A., Prescott, S. M., & McIntyre, T. M. (1992) · Immunology Today · doi:10.1016/0167-5699(92)90149-2 · Cited by 747
Grace, P. A. (1994) · Journal of British Surgery · doi:10.1002/bjs.1800810504 · Cited by 720
L-selectin-mediated lymphocyte rolling on MAdCAM-1
Berg, E. L., McEvoy, L. M., Berlin, C., Bargatze, R. F., & Butcher, E. C. (1993) · Nature · doi:10.1038/366695a0 · Cited by 536
Metadata
- Authors
- Perry, M. A., & Granger, D. N.
- Venue
- Journal of Clinical Investigation
- Published
- 1991-05-01
- Volume
- 87
- Issue
- 5
- Pages
- 1798-1804
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W1971178151
- Cited by
- 250
- References
- 0
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Role of CD11/CD18 in shear rate-dependent leukocyte-endothelial cell interactions in cat mesenteric venules. https://app.cochat.ai/papers/10.1172/jci115200
- The paper
- Perry, M. A., & Granger, D. N. (1991). Role of CD11/CD18 in shear rate-dependent leukocyte-endothelial cell interactions in cat mesenteric venules. Journal of Clinical Investigation. https://doi.org/10.1172/jci115200
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.