Cited by 231Cholesterol and Lipid MetabolismLipoproteins and Cardiovascular HealthLipid metabolism and disorders

Increased plasma and renal clearance of an exchangeable pool of apolipoprotein A-I in subjects with low levels of high density lipoprotein cholesterol

Open access
Horowitz, B S, Goldberg, I J, Merab, J, Vanni, T M, Ramakrishnan, R, Ginsberg, H N·1993·Journal of Clinical Investigation

Abstract

Plasma levels of HDL apo A-I are reduced in individuals with low HDL cholesterol (HDL-C) concentrations as a result of increased fractional catabolic rates (FCRs). To determine the basis for the high apo A-I FCRs, seven subjects with low HDL-C levels (31.0 +/- 4.3 mg/dl) were compared with three subjects with high HDL-C levels (72.0 +/- 4.5 mg/dl). Each subject received autologous HDL that was labeled directly by the iodine-monochloride method (whole-labeled) and autologous HDL that was labeled by exchange with homologous radiolabeled apo A-I (exchange-labeled). Blood was obtained for 2 wk, specific activities determined, and FCRs (d-1 +/- SD) estimated. In every subject, whether in the low or high HDL-C group, the exchange-labeled FCR was greater than the whole-labeled FCR. The exchange-labeled FCR was higher in the low HDL-C group (0.339 +/- 0.043) versus the high HDL-C group (0.234 +/- 0.047; P < 0.009). The whole-labeled FCR was also greater in the low HDL-C group (0.239 +/- 0.023) versus the high HDL-C group (0.161 +/- 0.064; P < 0.02). In addition, in both low and high HDL groups ultracentrifugation resulted in more radioactivity in d > 1.210 (as percentage of total plasma counts per minute) with the exchange-labeled tracer than with the whole-labeled tracer (12.55 +/- 4.95% vs. 1.02 +/- 0.38%; P < 0.003). With both HDL tracers, more radioactivity was found in d > 1.210 in the low versus the high HDL-C groups. When apo A-I catabolism was studied by perfusing isolated rabbit kidneys with whole-labeled HDL, there was twice as much accumulation (cpm/g cortex) of HDL apo A-I isolated from subjects with low HDL-C than from subjects with high HDL-C (P < 0.0025). Finally, HDL that had been isolated from subjects with high levels of HDL-C was triglyceride enriched and exposed to partially purified lipases before perfusion through kidneys. Threefold more apo A-I from modified HDL accumulated in the cortex compared with the unmodified preparation (P < 0.007). The results of these in vivo and ex vivo studies indicate that individuals with low HDL-C levels have more loosely bound, easily exchanged apo A-I and that this exchangeable apo A-I is more readily cleared by the kidney.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci116384

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Catabolism rather than production is the major determinant of HDL apoA-I levels.

    “These data suggest that catabolism rather than production is the major determinant of HDL apoA-I levels, as suggested by previous studies (43)(44)(45).”

    From Plasma turnover of HDL apoC-I, apoC-III, and apoE in humans (2003) · cites this paper as [44]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cited by

Sorted by citations

Authors
Horowitz, B. S., Goldberg, I. J., Merab, J., Vanni, T. M., Ramakrishnan, R., & Ginsberg, H. N.
Affiliations
  • Columbia University (US)
  • Columbia University Irving Medical Center (US)
Venue
Journal of Clinical Investigation
Published
1993-04-01
Volume
91
Issue
4
Pages
1743-1752
ISSN
0021-9738 (ISSN-L)
OpenAlex
W2078424668
Cited by
231
References
0
Citations by year
2026: 1 · 2025: 2 · 2023: 5 · 2022: 2 · 2021: 5 · 2020: 3 · 2019: 7 · 2018: 6 · 2017: 5 · 2016: 5 · 2015: 2 · 2014: 5 · 2013: 7 · 2012: 3
FWCI
14.91
Type
journal article
Language
en
Open access
Locations
  • Journal of Clinical Investigation (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • American Heart Association
  • Bristol-Myers Squibb
  • National Institutes of Health (5p50hl021006-17, 5r01hl036000-11)
  • National Heart, Lung, and Blood Institute (HL-36000, HL07343, HL 21006)
Topics
  • Health Sciences › Medicine › Surgery › Cholesterol and Lipid Metabolism
  • Health Sciences › Medicine › Surgery › Lipoproteins and Cardiovascular Health
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Lipid metabolism and disorders
Keywords
apolipoprotein A-I, HDL cholesterol, fractional catabolic rate, HDL catabolism, renal clearance, iodine-125 labeling, HDL subfractions, low HDL cholesterol, HDL metabolism
MeSH terms
Adult, Humans, Iodine Radioisotopes, Kidney, Kidney Cortex, Cholesterol, HDL, Male, Middle Aged, Apolipoprotein A-I

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review