Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 270

The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.

Nitric oxide may mediate the hemodynamic effects of recombinant growth hormone in patients with acquired growth hormone deficiency. A double-blind, placebo-controlled study.

Open access
Böger, R H, Skamira, C, Bode-Böger, S M, Brabant, G, von zur Muhlen, A, Frolich, J C · 1996 · Journal of Clinical Investigation

Abstract

We studied the effects of recombinant growth hormone on systemic nitric oxide (NO) formation and hemodynamics in a double-blind, placebo-controlled trial in adult patients with acquired growth hormone deficiency. 30 patients were randomly allocated to either recombinant human growth hormone (r-hGH; 2.0 IU/d) or placebo for 12 mo. In the subsequent 12 mo, the study was continued with both groups of patients receiving r-hGH. In months 1, 3, 6, 9, and 12 of each year, urine and plasma samples were collected for the determination of urinary nitrate and cyclic GMP as indices of systemic NO production, and of plasma IGF-1 levels. Cardiac output was measured in months 1, 12, and 24 by echocardiography. r-hGH induced a fourfold increase in plasma IGF-1 concentrations within the first month of treatment. Urinary nitrate and cyclic GMP excretion rates were low at baseline in growth hormone-deficient patients (nitrate, 96.8+/-7.4 micromol/mmol creatinine; cyclic GMP, 63.6+/-7.1 nmol/mmol creatinine) as compared with healthy controls (nitrate, 167.3+/-7.5 micromol/mmol creatinine; cyclic GMP, 155.2+/-6.9 nmol/mmol creatinine). These indices of NO production were significantly increased by r-hGH, within the first 12 mo in the GH group, and within the second 12 mo in the placebo group. While systolic and diastolic blood pressure were not significantly altered by r-hGH, cardiac output significantly increased by 30-40%, and total peripheral resistance decreased by approximately 30% in both groups when they were assigned to r-hGH treatment. In the second study year, when both groups were given r-hGH, there were no significant differences in plasma IGF-1, urinary nitrate, or cyclic GMP excretion, or hemodynamic parameters between both groups. In conclusion, systemic NO formation is decreased in untreated growth hormone-deficient patients. Treatment with recombinant human growth hormone normalizes urinary nitrate and cyclic GMP excretion, possibly via IGF-1 stimulation of endothelial NO formation, and concomitantly decreases peripheral arterial resistance. Increased NO formation may be one reason for improved cardiovascular performance of patients with acquired hypopituitarism during growth hormone therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci119095

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 52 references

Cited by

See all 270

Metadata

Authors
Böger, R. H., Skamira, C., Bode-Böger, S. M., Brabant, G., von zur Muhlen, A., & Frolich, J. C.
Venue
Journal of Clinical Investigation
Published
1996-12-15
Volume
98
Issue
12
Pages
2706-2713
ISSN
0021-9738 (ISSN-L)
OpenAlex
W2096700125
Cited by
270
References
52
FWCI
7.87
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nitric oxide may mediate the hemodynamic effects of recombinant growth hormone in patients with acquired growth hormone deficiency. A double-blind, placebo-controlled study. https://app.cochat.ai/papers/10.1172/jci119095
The paper
Böger, R. H., Skamira, C., Bode-Böger, S. M., Brabant, G., von zur Muhlen, A., & Frolich, J. C. (1996). Nitric oxide may mediate the hemodynamic effects of recombinant growth hormone in patients with acquired growth hormone deficiency. A double-blind, placebo-controlled study. Journal of Clinical Investigation. https://doi.org/10.1172/jci119095

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.