Infection Risk of Open Placement of Intraperitoneal Composite Mesh
The DOI matches its Crossref record.
Abstract
Mesh contamination is the most feared postoperative complication after ventral herniorrhaphy. The morbidity is significant requiring additional operative procedures for debridement or complete removal of the prosthesis. From July 1998 to December 2007, a retrospective review was performed to evaluate the incidence of mesh infection in patients undergoing an elective, open intra-abdominal sublay technique of repair using a composite mesh of polypropylene and expanded polytetrafluoroethylene (Composix®, Davol®, Inc., Cranston, RI). There were 206 procedures involving open, intraperitoneal placement of Composix® mesh resulting in 21 mesh infections (10.2%). The majority of infections were secondary to Staphylococcus aureus contamination (76%), and over half were infected with MRSA. All patients, except two, required mesh removal. Reoperation for repair of the recurrent defect after mesh removal was necessary in 67 per cent. Two patients with MRSA infection subsequently reinfected their recurrent repair. Overall, the infected group required 44 additional procedures (mean of 2.1 procedures/patient). The infection risk was reduced with the lighter density, newer generation composite mesh (7.3% vs 14.5%). Mesh infection after ventral herniorrhaphy conveys significant morbidity. An open intraabdominal underlay of a composite mesh of polypropylene and ePTFE carries a real risk of contamination and should be reconsidered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sartelli, M., Guirao, X., Hardcastle, T. C., Kluger, Y., Boermeester, M. A., Raşa, K., Ansaloni, L., Coccolini, F., Montravers, P., Abu-Zidan, F. M., et al. (2018) · World Journal of Emergency Surgery · doi:10.1186/s13017-018-0219-9 · Cited by 301
Rosen, M. J., Bauer, J. J., Harmaty, M., Carbonell, A. M., Cobb, W. S., Matthews, B., Goldblatt, M. I., Selzer, D. J., Poulose, B. K., Hansson, B. M. E., et al. (2017) · Annals of Surgery · doi:10.1097/sla.0000000000001601 · Cited by 259
Self-citationMesh Infection in Ventral Incisional Hernia Repair: Incidence, Contributing Factors, and Treatment
Sanchez, V. M., Abi-Haidar, Y. E., & Itani, K. M. F. (2011) · Surgical Infections · doi:10.1089/sur.2011.033 · Cited by 194
“One study analyzed risk factors for mesh infection after open VIH repair in 751 patients, and failed to demonstrate any association of infection with patient factors [5].”
Li, X., Sun, H., Lin, N., Hou, X., Wang, J., Zhou, B., Xu, P., Xiao, Z., Chen, B., Dai, J., et al. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.07.050 · Cited by 158
“However, PTFE and PU/PLLA are nonabsorbable and may cause serious infections and adhesions [7,9]; SIS is thought to be able to promote tissue regeneration but does not provide enough mechanical strength when used in the replacement of large defect [10].”
BackgroundMavros, M. N., Athanasiou, S., Alexiou, V. G., Mitsikostas, P. K., Peppas, G., & Falagas, M. E. (2011) · World Journal of Surgery · doi:10.1007/s00268-011-1266-5 · Cited by 158
Metadata
- Authors
- Cobb, W. S., Carbonell, A. M., Kalbaugh, C. L., Jones, Y., & Lokey, J. S.
- Venue
- The American Surgeon™
- Publisher
- SAGE Publications
- Published
- 2009-09
- Volume
- 75
- Issue
- 9
- Pages
- 762-768
- ISSN
- 0003-1348 (ISSN-L)
- 1555-9823
- OpenAlex
- W1540893380
- Cited by
- 135
- References
- 0
- FWCI
- 7.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.