Site of Airway Collapse in Obstructive Sleep Apnea after Uvulopalatopharyngoplasty
The DOI matches its Crossref record.
Abstract
The objective of this prospective study was to determine the site and pattern of upper airway collapse by a multiple-catheter technique in subjects demonstrated to have obstructive sleep apnea (OSA) after uvulopalatopharyngoplasty (UPPP). Standard diagnostic nocturnal polysomnography (PSG) was done on all subjects. The PSG recordings included electroencephalogram, electro-oculogram, electrocardiogram, chin and leg electromyograms, nasal and oral airflow, and abdominal effort. Polysomnography with a multiport flexible airway Gaeltec catheter was performed in 22 subjects. The Gaeltec flexible airway catheter has 4 high-fidelity pressure sensors to aid in determining the primary site of airway collapse. The primary site of airway collapse was determined by differential pressure gradients between pressure ports and by visual inspection of the pressure tracings. Forty-two subjects with prior UPPP from a total of 60 (39 men and 3 women, ages 33 to 61) agreed to be to studied by the standard PSG technique. Thirty-five subjects complained of excessive daytime sleepiness. Ten had mild OSA, 10 had moderate OSA, 12 had severe OSA, and 10 were “normal.” Of the 22 subjects who had airway catheter monitoring, 3 of the normals were reclassified as having upper airway resistance (mean peak negative esophageal pressure of —28 cm H 2 O); 2 patients demonstrated airway obstruction in the nasopharynx, 2 at the oropharynx, and 11 at the level of the hypopharynx. Postoperative nocturnal PSG data were compared to data gathered prior to UPPP. The mean respiratory disturbance index (RDI) for the catheter group was 54 events per hour prior to UPPP, and the mean RDI after surgery was 44. There was no correlation between the severity of OSA and the stage of sleep. We conclude that the majority of patients who complain of excessive daytime sleepiness following UPPP have OSA with the primary site of obstruction at the level of the hypopharynx. The severity of airway collapse is variable during each stage of sleep. Esophageal pressure monitoring during sleep should be considered when evaluating symptoms of persistent OSA in patients who have had UPPP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kezirian, E. J. (2011) · The Laryngoscope · doi:10.1002/lary.21749 · Cited by 129
Radiofrequency Ablation for the Treatment of Mild to Moderate Obstructive Sleep Apnea
Blumen, M. B., Dahan, S., Fleury, B., Hausser‐Hauw, C., & Chabolle, F. (2002) · The Laryngoscope · doi:10.1097/00005537-200211000-00033 · Cited by 79
Structural effectiveness of pharyngeal sleep apnea surgery
Tucker Woodson, B. (2008) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2008.07.010 · Cited by 46
Li, H.-Y., Li, K. K., Chen, N.-H., Wang, C.-J., Liao, Y.-F., & Wang, P.-C. (2005) · American Journal of Otolaryngology · doi:10.1016/j.amjoto.2004.06.006 · Cited by 45
Metadata
- Authors
- Farmer, W. C., & Giudici, S. C.
- Venue
- Annals of Otology, Rhinology & Laryngology
- Publisher
- SAGE Publications
- Published
- 2000-06
- Volume
- 109
- Issue
- 6
- Pages
- 581-584
- ISSN
- 0003-4894 (ISSN-L)
- 1943-572X
- OpenAlex
- W2325575685
- Cited by
- 40
- References
- 0
- FWCI
- 1.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Site of Airway Collapse in Obstructive Sleep Apnea after Uvulopalatopharyngoplasty. https://app.cochat.ai/papers/10.1177/000348940010900609
- The paper
- Farmer, W. C., & Giudici, S. C. (2000). Site of Airway Collapse in Obstructive Sleep Apnea after Uvulopalatopharyngoplasty. Annals of Otology, Rhinology & Laryngology. https://doi.org/10.1177/000348940010900609
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.