Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 192

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Comparison of High-Speed Digital Imaging with Stroboscopy for Laryngeal Imaging of Glottal Disorders

Patel, Rita, Dailey, Seth, Bless, Diane · 2008 · Annals of Otology, Rhinology & Laryngology

Abstract

Objectives: High-speed digital imaging (HSDI), unlike stroboscopy, is a frequency-independent visualization technique that provides detailed biomechanical assessment of vocal physiology due to increased temporal resolution. The purpose of this study was to investigate the clinical value of HSDI compared to that of stroboscopy across 3 disorder groups classified as epithelial, subepithelial, and neurologic disorders. Methods: Judgments of vibratory features of vocal fold edge, glottal closure, phase closure, vertical level, vibratory amplitude, mucosal wave, phase symmetry, tissue pliability, and glottal cycle periodicity from 252 participants were performed by 3 experienced raters. Results: The results revealed that 63% of the data set was noninterpretable for assessment of vibratory function on stroboscopic analysis because of the severity of the voice disorder (100% of participants with severe voice disorders and 64% of participants with moderate voice disorders), whereas HSDI resulted in analysis of 100% of the data. The neuromuscular group (74%) was the most difficult to analyze with stroboscopy, followed by the epithelial (58%) and subepithelial groups (53%), secondary to the severity of hoarseness. Conclusions: Because it is desirable in clinical examination to observe vocal fold vibrations, which cannot be done in cases of severe dysphonia, HSDI may aid in clinical decision-making when patients exhibit values exceeding 0.87% jitter, 4.4% shimmer, and a signal-to-noise ratio of less than 15.4 dB on acoustic analysis. These measures could serve as minimal indications for use of HSDI. The data suggest that HSDI can be viewed as augmentative to stroboscopy, particularly in cases of moderate to severe aperiodicity, in which HSDI may aid clinical decision-making.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/000348940811700603

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 192

Metadata

Authors
Patel, R., Dailey, S., & Bless, D.
Venue
Annals of Otology, Rhinology & Laryngology
Published
2008-06
Volume
117
Issue
6
Pages
413-424
ISSN
  • 0003-4894 (ISSN-L)
  • 1943-572X
OpenAlex
W1968696771
Cited by
192
References
1
FWCI
5.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of High-Speed Digital Imaging with Stroboscopy for Laryngeal Imaging of Glottal Disorders. https://app.cochat.ai/papers/10.1177/000348940811700603
The paper
Patel, R., Dailey, S., & Bless, D. (2008). Comparison of High-Speed Digital Imaging with Stroboscopy for Laryngeal Imaging of Glottal Disorders. Annals of Otology, Rhinology & Laryngology. https://doi.org/10.1177/000348940811700603

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.