The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Comparison of High-Speed Digital Imaging with Stroboscopy for Laryngeal Imaging of Glottal Disorders
Abstract
Objectives: High-speed digital imaging (HSDI), unlike stroboscopy, is a frequency-independent visualization technique that provides detailed biomechanical assessment of vocal physiology due to increased temporal resolution. The purpose of this study was to investigate the clinical value of HSDI compared to that of stroboscopy across 3 disorder groups classified as epithelial, subepithelial, and neurologic disorders. Methods: Judgments of vibratory features of vocal fold edge, glottal closure, phase closure, vertical level, vibratory amplitude, mucosal wave, phase symmetry, tissue pliability, and glottal cycle periodicity from 252 participants were performed by 3 experienced raters. Results: The results revealed that 63% of the data set was noninterpretable for assessment of vibratory function on stroboscopic analysis because of the severity of the voice disorder (100% of participants with severe voice disorders and 64% of participants with moderate voice disorders), whereas HSDI resulted in analysis of 100% of the data. The neuromuscular group (74%) was the most difficult to analyze with stroboscopy, followed by the epithelial (58%) and subepithelial groups (53%), secondary to the severity of hoarseness. Conclusions: Because it is desirable in clinical examination to observe vocal fold vibrations, which cannot be done in cases of severe dysphonia, HSDI may aid in clinical decision-making when patients exhibit values exceeding 0.87% jitter, 4.4% shimmer, and a signal-to-noise ratio of less than 15.4 dB on acoustic analysis. These measures could serve as minimal indications for use of HSDI. The data suggest that HSDI can be viewed as augmentative to stroboscopy, particularly in cases of moderate to severe aperiodicity, in which HSDI may aid clinical decision-making.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Task specificity in adductor spasmodic dysphonia versus muscle tension dysphonia
Roy, N., Gouse, M., Mauszycki, S. C., Merrill, R. M., & Smith, M. E. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000154739.48314.ee · Cited by 113
Cited by
Patel, R. R., Awan, S. N., Barkmeier-Kraemer, J., Courey, M., Deliyski, D., Eadie, T., Paul, D., Švec, J. G., & Hillman, R. (2018) · American Journal of Speech-Language Pathology · doi:10.1044/2018_ajslp-17-0009 · Cited by 818
Self-citationClinical Practice Guideline: Hoarseness (Dysphonia)
Schwartz, S. R., Cohen, S. M., Dailey, S. H., Rosenfeld, R. M., Deutsch, E. S., Gillespie, M. B., Granieri, E., Hapner, E. R., Kimball, C. E., Krouse, H. J., et al. (2009) · Otolaryngology–Head and Neck Surgery · doi:10.1016/j.otohns.2009.06.744 · Cited by 453
Self-citationSpasmodic dysphonia: a review. Part 2: characterization of pathophysiology
Hintze, J. M., Ludlow, C. L., Bansberg, S. F., Adler, C. H., & Lott, D. G. (2017) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599817728465 · Cited by 76
Metadata
- Authors
- Patel, R., Dailey, S., & Bless, D.
- Venue
- Annals of Otology, Rhinology & Laryngology
- Publisher
- SAGE Publications
- Published
- 2008-06
- Volume
- 117
- Issue
- 6
- Pages
- 413-424
- ISSN
- 0003-4894 (ISSN-L)
- 1943-572X
- OpenAlex
- W1968696771
- Cited by
- 192
- References
- 1
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of High-Speed Digital Imaging with Stroboscopy for Laryngeal Imaging of Glottal Disorders. https://app.cochat.ai/papers/10.1177/000348940811700603
- The paper
- Patel, R., Dailey, S., & Bless, D. (2008). Comparison of High-Speed Digital Imaging with Stroboscopy for Laryngeal Imaging of Glottal Disorders. Annals of Otology, Rhinology & Laryngology. https://doi.org/10.1177/000348940811700603
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.