CoChat

High-Resolution Manometry of Pharyngeal Swallow Pressure Events Associated with Head Turn and Chin Tuck

Open access
Mcculloch, Timothy M., Hoffman, Matthew R., Ciucci, Michelle R. · 2010 · Annals of Otology, Rhinology & Laryngology
Cited by 165

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Objectives: We quantified the effect of swallowing maneuvers on pharyngeal pressure events using high-resolution manometry. Methods: Seven subjects swallowed multiple 5-mL water boluses in 3 different postural conditions: neutral, head turn, and chin tuck. Pressure and timing events were recorded with a 36-sensor high-resolution manometry catheter. We analyzed the regions of the velopharynx and the base of the tongue for maximum pressure, rate of pressure increase, pressure gradient, and duration of pressure above baseline. In the region of the upper esophageal sphincter (UES), we analyzed the duration of pressure declination, minimum pressure during UES opening, and maximum pressures before and after UES opening. Results: The maneuvers did not have a significant effect on maximum pressure, rate of pressure increase, or pressure gradients in the velopharyngeal or tongue base regions. The duration of pressure above baseline was significantly longer in the velopharynx for head turn. The preswallow maximum UES pressure was significantly greater for neutral swallows than for head turn, and the postswallow maximum pressure was significantly lower for chin tuck. Both maneuvers appeared to prolong UES pressure declination duration, but neither prolongation reached significance. Conclusions: High-resolution manometry allows for optimal spatial and temporal resolution during recording of pressure events along the length of the pharynx, and revealed previously undetected task-dependent pressure and timing differences during chin tuck and head turn in healthy adults. These maneuvers appear to influence the UES to a greater degree than the velopharynx or the tongue base. Further studies designed to quantify the effect of other maneuvers and bolus consistencies on the generation of pharyngeal pressure events both in normal and in disordered subjects may lead to hypothesis-driven, optimal, individualized swallowing therapies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/000348941011900602

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

Metadata

Authors
Mcculloch, T. M., Hoffman, M. R., & Ciucci, M. R.
Venue
Annals of Otology, Rhinology & Laryngology
Published
2010-06
Volume
119
Issue
6
Pages
369-376
ISSN
  • 0003-4894 (ISSN-L)
  • 1943-572X
OpenAlex
W1490578302
Cited by
165
References
17
FWCI
18.93
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.