The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Multi-material 3D Models for Temporal Bone Surgical Simulation
Abstract
Hypothesis: A simulated, multicolor, multi-material temporal bone model can be created using 3-dimensional (3D) printing that will prove both safe and beneficial in training for actual temporal bone surgical cases. Background: As the process of additive manufacturing, or 3D printing, has become more practical and affordable, a number of applications for the technology in the field of Otolaryngology–Head and Neck Surgery have been considered. One area of promise is temporal bone surgical simulation. Methods: Three-dimensional representations of human temporal bones were created from temporal bone computed tomography (CT) scans using biomedical image processing software. Multi-material models were then printed and dissected in a temporal bone laboratory by attending and resident otolaryngologists. A 5-point Likert scale was used to grade the models for their anatomical accuracy and suitability as a simulation of cadaveric and operative temporal bone drilling. Results: The models produced for this study demonstrate significant anatomic detail and a likeness to human cadaver specimens for drilling and dissection. Conclusion: Simulated temporal bones created by this process have potential benefit in surgical training, preoperative simulation for challenging otologic cases, and the standardized testing of temporal bone surgical skills.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of Reducing Interns' Work Hours on Serious Medical Errors in Intensive Care Units
Landrigan, C. P., Rothschild, J. M., Cronin, J. W., Kaushal, R., Burdick, E., Katz, J. T., Lilly, C. M., Stone, P. H., Lockley, S. W., Bates, D. W., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041406 · Cited by 1,760
Ahmed, N., Devitt, K. S., Keshet, I., Spicer, J., Imrie, K., Feldman, L., Cools-Lartigue, J., Kayssi, A., Lipsman, N., Elmi, M., et al. (2014) · Annals of Surgery · doi:10.1097/sla.0000000000000595 · Cited by 516
Cited by
Hoang, D., Perrault, D., Stevanovic, M., & Ghiassi, A. (2016) · Annals of Translational Medicine · doi:10.21037/atm.2016.12.18 · Cited by 317
3D printing and modelling of customized implants and surgical guides for non-human primates.
Chen, X., Possel, J. K., Wacongne, C., van Ham, A. F., Klink, P. C., & Roelfsema, P. R. (2017) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2017.05.013 · Cited by 106
Metadata
- Authors
- Rose, A. S., Kimbell, J. S., Webster, C. E., Harrysson, O. L. A., Formeister, E. J., & Buchman, C. A.
- Venue
- Annals of Otology, Rhinology & Laryngology
- Publisher
- SAGE Publications
- Published
- 2015-02-06
- Volume
- 124
- Issue
- 7
- Pages
- 528-536
- ISSN
- 0003-4894 (ISSN-L)
- 1943-572X
- OpenAlex
- W2120424207
- Cited by
- 162
- References
- 2
- FWCI
- 8.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multi-material 3D Models for Temporal Bone Surgical Simulation. https://app.cochat.ai/papers/10.1177/0003489415570937
- The paper
- Rose, A. S., Kimbell, J. S., Webster, C. E., Harrysson, O. L. A., Formeister, E. J., & Buchman, C. A. (2015). Multi-material 3D Models for Temporal Bone Surgical Simulation. Annals of Otology, Rhinology & Laryngology. https://doi.org/10.1177/0003489415570937
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.