The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Review of Existing Standards, Guides, and Practices for Raman Spectroscopy
Open accessAbstract
Over the past decades Raman spectroscopy has been extensively used both on an industrial and academic level. This has resulted in the development of numerous specialized Raman techniques and Raman active products, which in turn has led to the adoption and development of standards and norms pertaining to Raman unit’s calibration, performance validation, and interoperability. Purpose of the present review is to list, classify, and engage in a comprehensive analysis of the different standards, guides, and practices relating to Raman spectroscopy. Primary aim of the review is to consider the commonalities and conflicts between these standards and norms and to identify any missing aspects. Standardization in the field of Raman spectroscopy is dominated by the work of American institutions, namely, the American Society of Testing Materials (ASTM or ASTM International), with several active standards in place pertaining to terminology, calibration, multivariate analysis, and specific applications, and the National Institute of Standards and Technology (NIST), providing numerous certified reference materials, referred to as standard reference materials. The industrial application of Raman spectroscopy is dominated by the pharmaceutical industry. As such, pharmacopoeias provide not only important information in relation to pharmaceutical-related applications of Raman spectroscopy, but also invaluable insight, into the basic principles of Raman spectroscopy and important aspects that include calibration, validation, measurement, and chemometric analysis processes, usually by referring to ASTM and NIST standards. Given the fact that Raman spectroscopy is a modern and innovative field, the standardization processes are complex and constantly evolving. Despite the seemingly high number of existing standards, the standardization landscape is incomplete and has not been modernized according to the developments in Raman spectroscopy techniques in recent years. This is evident by the lack of protocols for numerous areas as well as by the fact that some of the existing standards have not been updated to reflect the advances in the technique. Therefore, it is important for the Raman community to actively engage in and contribute to a modernization process that will result in updating existing and introducing new terms, protocols, and guides. Indeed, the development of optimized common standards would be extremely beneficial and would further foster the development and application of Raman spectroscopy techniques, most notably those of surface enhanced Raman spectroscopy and low-resolution portable analyzers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“However, there is little concrete description of how quantitation is affected by one’s choice of numerical unmixing algorithm and the nature of the spectral bands being scrutinized, and little has been done to create consistent standard samples to interrogate quantitation robustness.21,22”
From Assessment of unmixing approaches for the quantitation of SERS nanoparticles in highly multiplexed spectral images (2024) · cites this paper as [22]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International Organization for Standardization (ISO)
Nahler, G. (2009) · Dictionary of Pharmaceutical Medicine · doi:10.1007/978-3-211-89836-9_723 · Cited by 3,674
The Egyptian Labor Market in an Era of RevolutionPreprint
Assaad, R. A., & Krafft, C. (2015) · RePEc: Research Papers in Economics · doi:10.1093/acprof · Cited by 2,480
Raman Spectroscopy for Chemical Analysis
McCreery, R. L. (2000) · Wiley eBooks · doi:10.1002/0471721646 · Cited by 1,469
Postulated Carbon Tetrachloride Mode of Action: A Review
Manibusan, M. K., Odin, M., & Eastmond, D. A. (2007) · Journal of Environmental Science and Health Part C · doi:10.1080/10590500701569398 · Cited by 445
Structural phase transitions of syndiotactic polystyrene
Gowd, E. B., Tashiro, K., & Ramesh, C. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.11.002 · Cited by 180
Choquette, S. J., Etz, E. S., Hurst, W. S., et al. (2007) · Applied Spectroscopy · doi:10.1366/000370207779947585 · Cited by 125
Comparability of Raman Spectroscopic Configurations: A Large Scale Cross-Laboratory Study
Guo, S., Beleites, C., Neugebauer, U., Abalde‐Cela, S., Afseth, N. K., Alsamad, F., Anand, S., Araujo-Andrade, C., Aškrabić, S., Avcı, E., et al. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c02696 · Cited by 111
Chemometrics for Raman Spectroscopy Harmonization
Barton, B., Thomson, J., Lozano Diz, E., & Portela, R. (2022) · Applied Spectroscopy · doi:10.1177/00037028221094070 · Cited by 79
Self-citationGómez, D. A., Coello, J., & Maspoch, S. (2018) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2018.10.011 · Cited by 73
Ray, K. G., & McCreery, R. L. (1997) · Applied Spectroscopy · doi:10.1366/0003702971938849 · Cited by 70
Research works printed but not linked: 43
- Joerges C., 1991, EUI Working Paper; LAW Nos. 91/10-14
- Bennet H.S., 1975, NBSIR 75-759: Standard Reference Materials and Data for Raman Spectroscopy, Electron Paramagnetic Resonance, and Magnetic Moment Measurements
- McNaught A.D., 1997, IUPAC Compendium of Chemical Terminology: The Gold Book
- International Organization for Standardization (ISO), ”
- ASTM International, 2015, ASTM E131-10 Standard Terminology Relating to Molecular Spectroscopy
- 10.1520/E2642-09R15.2 · DOI
- 10.1520/E2719-09R14.2 · DOI
- ASTM International, 2014, ASTM E1840–96 Standard Guide for Raman Shift Standards for Spectrometer Calibration
- ASTM International, 2014, ASTM E2529–06 Standard Guide for Testing the Resolution of a Raman Spectrometer
- 10.1520/E1683-02R14E01.2 · DOI
- de Fouw J., 1999, Carbon Tetrachloride
- ASTM International, 2014, ASTM E387-04 Standard Test Method for Estimating Stray Radiant Power Ratio of Dispersive Spectrophotometers by the Opaque Filter Method
- 10.1520/E1840-96R14.2 · DOI
- 10.1520/E1654-94R13.2 · DOI
- 10.1520/E1654-94R13.2 · DOI
- 2020, European Directorate for the Quality of Medicines and Healthcare. “Raman Spectroscopy”. European Pharmacopoeia
- 10.31003/USPNF_M8188_02_01 · DOI
- National Institute of Metrology (NIM), 2012, JJF 1343-2012. General and Statistical Principles for Characterization of Reference Materials
- Kramida A., 2021, Atomic Spectra Database: NIST Standard Reference Database 78
- National Institute of Standards and Technology (NIST), 2022, SRM 2241 Relative Intensity Correction Standard for Raman Spectroscopy: 785 nm Excitation
- National Institute of Standards and Technology (NIST), 2019, SRM 2242a. Relative Intensity Correction Standard for Raman Spectroscopy: 532 nm Excitation
- National Institute of Standards and Technology (NIST), 2009, SRM 2243. Relative Intensity Correction Standard for Raman Spectroscopy: 488 nm and 514.5 nm Excitation
- National Institute of Standards and Technology (NIST), 2020, SRM 2244. Relative Intensity Correction Standard for Raman Spectroscopy: 1064 nm Excitation
- National Institute of Standards and Technology (NIST), 2013, SRM 2245. Relative Intensity Correction Standard for Raman Spectroscopy: 633 nm Excitation
- National Institute of Standards and Technology (NIST), 2015, SRM 2246. Relative Intensity Correction Standard for Raman Spectroscopy: 830 nm Excitation
- National Institute of Metrology, 2018, GBW13650. Relative Intensity Standard Material for Raman Spectroscopy: 514.5 nm Excitation
- National Institute of Metrology, 2019, GBW13651. Raman Shift Standards for Spectrometer Calibration: Sulfur
- National Institute of Metrology, 2020, GBW13652. Raman Shift Standards for Spectrometer Calibration: Naphthalene
- National Institute of Metrology, 2019, GBW13653. Raman Shift Standards for Spectrometer Calibration: Cyclohexane
- National Institute of Metrology, 2019, GBW13654. Raman Shift Standards for Spectrometer Calibration: 4-Acetamidothiopnenol
- National Metrology Institute of Japan, 2020, CRM 5606-A. Single Crystal Silicon for Positron Defect Measurements
- National Institute of Metrology, GBW13664. Raman Shift Standards for Spectrometer Calibration: Polystyrene
- National Metrology Institute of Japan (NMIJ), 2020, RM 8158-A. Polystyrene for Raman Spectrometer
- International Electrotechnical Commission (IEC), 2021, IEC 60825-2:2021 Safety of Laser Products–Part 2: Safety of Optical Fiber Communication Systems (OFCSS)
- IEC TS 62607-6-6 ED1, Nanomanufacturing - Key control characteristics - Part 6-6: Graphene - Strain uniformity: Raman spectroscoopy. n.d
- IEC TS 62607-6-11 ED1, Nanomanufacturing - Key control characteristics - Part 6-11: Graphene-based Material - Defect density: Raman spectroscopy. n.d
- IEC. PNW TS 113-570 ED1, Nanomanufacturing – Key Control Characteristics – Part 6-12: Graphene-based material – Number of layers: Raman spectroscopy, optical reflection. n.d
- IEC TS 62607-6-14:2020, Nanomanufacturing - Key control characteristics - Part 6-14: Graphene-based material - Defect level: Raman spectroscopy. n.d
- IEC. PNW TS 113-580 ED1, Nanomanufacturing - Key control characteristics - Part 6-29: Graphene-based materials - Defectiveness: Raman spectroscopy. n.d
- ISO/TS 21356-1, 2021, Nanotechnologies — Structural characterization of graphene — Part 1: Graphene from powders and dispersions
- Mamedov S., 2020, Spectrosc. Online, 35, 41
- ASTM International, 2021, ASTM E178–21 Standard Practice for Dealing with Outlying Observations
- ASTM International, 2017, ASTM E2617–17 Standard Practice for Validation of Empirically Derived Multivariate Calibrations
Cited by
Chemometrics for Raman Spectroscopy Harmonization
Barton, B., Thomson, J., Lozano Diz, E., & Portela, R. (2022) · Applied Spectroscopy · doi:10.1177/00037028221094070 · Cited by 79
Self-citationCzaja, A., Awad, S., Eremina, O. E., Fernando, A., & Zavaleta, C. (2024) · Journal of Raman Spectroscopy · doi:10.1002/jrs.6653 · Cited by 8
Metadata
- Authors
- Ntziouni, A., Thomson, J., Xiarchos, I., Li, X., Bañares, M. A., Charitidis, C., Portela, R., & Lozano Diz, E.
- Affiliations
- National Technical University of Athens (GR)
- ELODIZ Ltd., High Wycombe, Buckinghamshire, UK
- Consejo Superior de Investigaciones Científicas (ES)
- Institute of Catalysis and Petrochemistry (ICP), Spanish National Council for Scientific Research (CSIC), Madrid, Spain
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2022-05-23
- Volume
- 76
- Issue
- 7
- Pages
- 747-772
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W4220699913
- Cited by
- 73
- References
- 40
- Citations by year
- 2026: 18 · 2025: 27 · 2024: 17 · 2023: 8 · 2022: 3
- FWCI
- 2.12
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- Applied Spectroscopy (publishedVersion)
- PubMed (publishedVersion)
- DIGITAL.CSIC (Spanish National Research Council (CSIC)) (submittedVersion, other-oa)
- Funders
- European Commission (CHARISMA (GA95921))
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Keywords
- Raman spectroscopy, standardization, NIST standard reference materials, performance validation, interoperability, pharmacopoeia, pharmaceutical applications, surface-enhanced Raman spectroscopy, chemometrics, multivariate analysis, terminology
- MeSH terms
- Calibration, Reference Standards, Spectrum Analysis, Raman
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Review of Existing Standards, Guides, and Practices for Raman Spectroscopy. https://app.cochat.ai/papers/10.1177/00037028221090988
- The paper
- Ntziouni, A., Thomson, J., Xiarchos, I., Li, X., Bañares, M. A., Charitidis, C., Portela, R., & Lozano Diz, E. (2022). Review of Existing Standards, Guides, and Practices for Raman Spectroscopy. Applied Spectroscopy. https://doi.org/10.1177/00037028221090988
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.