Geometrical focusing of cells in a microfluidic device: An approach to separate blood plasma
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
It is well known that when a suspension of cells flows in small vessels (arterioles or venules), there exists a cell-free layer of a few microns adjacent to the vascular walls. Using an in vitro model, we show experimentally that for a fixed flow rate a geometrical constriction in the flow can artificially enhance the cell-free layer. Also, we show that rapid variation of the geometry coupled to the deformability of the cells can dramatically modify their spatial distribution in the channel. The effects of the constriction geometry, flow rate, suspending fluid viscosity, cell concentration, and cell deformability are studied and the results are interpreted in terms of a model of the hydrodynamic drift of an ellipsoidal cell in a shear flow. We propose a microfluidic application of this focusing effect for separation of the red blood cells from the suspending plasma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288 · cited 1×
“The microfluidic experiments used relief molds that were produced using common soft-lithography techniques [6].”
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800 · cited 1×
“During the last decade, microfluidic approaches have led to many developments toward a “lab-on-a-chip” [2].”
Biophysical aspects of blood flow in the microvasculature
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (1996) · Cardiovascular Research · doi:10.1016/s0008-6363(96)00065-x · Cited by 553
Fischer, T. M., Stöhr-Liesen, M., & Schmid-Schönbein, H. (1978) · Science · doi:10.1126/science.715448 · Cited by 427
An experimental investigation of concentrated suspension flows in a rectangular channel
Koh, C. J., Hookham, P., & Leal, L. G. (1994) · Journal of Fluid Mechanics · doi:10.1017/s0022112094000911 · Cited by 303 · cited 2×
“with the drift velocity given by [16]”
Robin Fahraeus: evolution of his concepts in cardiovascular physiology
Goldsmith, H. L., Cokelet, G. R., & Gaehtgens, P. (1989) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1989.257.3.h1005 · Cited by 231 · cited 3×
“Indeed, one of the oldest and best known hemodynamic phenomenon of the microcirculation is the Fåhraeus effect [11,19], which refers to the decreased hematocrit concentration in small tubes relative to the larger reservoirs to which they are connected [1].”
Biomimetic Autoseparation of Leukocytes from Whole Blood in a Microfluidic Device
Shevkoplyas, S. S., Yoshida, T., Munn, L. L., & Bitensky, M. W. (2005) · Analytical Chemistry · doi:10.1021/ac049037i · Cited by 225 · cited 1×
“The approach introduced for separation in this paper can be readily integrated into existing lab-on-a-chip microdevices [22,23].”
Flow behaviour of erythrocytes - I. Rotation and deformation in dilute suspensions
Goldsmith, H. L., Marlow, J., & MacIntosh, F. C. (1972) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1972.0084 · Cited by 220
Axial Migration of Particles in Poiseuille Flow
KARNIS, A., GOLDSMITH, H. L., & MASON, S. G. (1963) · Nature · doi:10.1038/200159a0 · Cited by 203 · cited 2×
“In this section we present experimental observations of a narrow cell-free layer upstream of the constriction [13,15] and document how this cell-free layer is substantially enhanced downstream of the obstruction.”
Generalization of the Fahraeus principle for microvessel networks
Pries, A. R., Ley, K., & Gaehtgens, P. (1986) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1986.251.6.h1324 · Cited by 198 · cited 2×
“Indeed, one of the oldest and best known hemodynamic phenomenon of the microcirculation is the Fåhraeus effect [11,19], which refers to the decreased hematocrit concentration in small tubes relative to the larger reservoirs to which they are connected [1].”
Recent advances in blood‐related proteomics
Thadikkaran, L., Siegenthaler, M. A., Crettaz, D., Queloz, P., Schneider, P., & Tissot, J. (2005) · PROTEOMICS · doi:10.1002/pmic.200402053 · Cited by 184 · cited 1×
“Hence, analyses of the plasma are used intensively in clinical hematology to study infections and diseases [25].”
Rheology of the microcirculation.
Pries, A. R., & Secomb, T. W. (2003) · PubMed · Cited by 179
Prototype of an in vitro model of the microcirculation
Shevkoplyas, S. S., Gifford, S. C., Yoshida, T., & Bitensky, M. W. (2003) · Microvascular Research · doi:10.1016/s0026-2862(02)00034-1 · Cited by 94 · cited 1×
“The approach introduced for separation in this paper can be readily integrated into existing lab-on-a-chip microdevices [22,23].”
Rheology of dilute suspensions of red blood cells: experimental and theoretical approaches
Drochon, A. (2003) · The European Physical Journal Applied Physics · doi:10.1051/epjap:2003024 · Cited by 32 · cited 1×
“The rigidity of the red blood cells was modified using a standard method [5].”
Cited by
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708
Label-free cell separation and sorting in microfluidic systems
Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3721-9 · Cited by 930
Particle separation and sorting in microfluidic devices: a review
Sajeesh, P., & Sen, A. K. (2014) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1291-9 · Cited by 767
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Deformability-based cell classification and enrichment using inertial microfluidics
Hur, S. C., Henderson-MacLennan, N. K., McCabe, E. R. B., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c0lc00595a · Cited by 576
Metadata
- Authors
- Faivre, M., Abkarian, M., Bickraj, K., & Stone, H. A.
- Venue
- Biorheology: The Official Journal of the International Society of Biorheology
- Publisher
- SAGE Publications
- Published
- 2006-03
- Volume
- 43
- Issue
- 2
- Pages
- 147-159
- ISSN
- 0006-355X (ISSN-L)
- 1878-5034
- OpenAlex
- W2111078625
- Cited by
- 196
- References
- 14
- FWCI
- 6.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.