Cited by 67Human-Automation Interaction and SafetyElectronic Health Records SystemsClinical Reasoning and Diagnostic Skills

The effect of cognitive load and task complexity on automation bias in electronic prescribing

Lyell, David, Magrabi, Farah, Coiera, Enrico·2018·Human Factors: The Journal of the Human Factors and Ergonomics Society

Abstract

Objective: Determine the relationship between cognitive load (CL) and automation bias (AB). Background: Clinical decision support (CDS) for electronic prescribing can improve safety but introduces the risk of AB, where reliance on CDS replaces vigilance in information seeking and processing. We hypothesized high CL generated by high task complexity would increase AB errors. Method: One hundred twenty medical students prescribed medicines for clinical scenarios using a simulated e-prescribing system in a randomized controlled experiment. Quality of CDS (correct, incorrect, and no CDS) and task complexity (low and high) were varied. CL, omission errors (failure to detect prescribing errors), and commission errors (acceptance of false positive alerts) were measured. Results: Increasing complexity from low to high significantly increased CL, F(1, 118) = 71.6, p < .001. CDS reduced CL in high-complexity conditions compared to no CDS, F(2, 117) = 4.72, p = .015. Participants who made omission errors in incorrect and no CDS conditions exhibited lower CL compared to those who did not, F(1, 636.49) = 3.79, p = .023. Conclusion: Results challenge the notion that AB is triggered by increasing task complexity and associated increases in CL. Omission errors were associated with lower CL, suggesting errors may stem from an insufficient allocation of cognitive resources. Application: This is the first research to examine the relationship between CL and AB. Findings suggest designers and users of CDS systems need to be aware of the risks of AB. Interventions that increase user vigilance and engagement may be beneficial and deserve further investigation.

Integrity signals

Registry

Crossref · 10.1177/0018720818781224

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Automation bias has been found to be a serious problem in contexts of AI-based decision support systems.

    “Automation bias has been found to be a serious problem in contexts of AI-based decision support systems (Mosier and Skitka, 1999; Goddard et al., 2012; Lyell et al., 2018; Davis et al., 2020)”

    From Check the box! How to deal with automation bias in AI-based personnel selection (2023) · cites this paper as Lyell et al., 2018

The citation lists haven’t been fetched yet

References 49 · Cited by 67

Authors
Lyell, D., Magrabi, F., & Coiera, E.
Affiliations
Macquarie University (AU)
Corresponding author
Lyell, David
Venue
Human Factors: The Journal of the Human Factors and Ergonomics Society
Published
2018-06-25
Volume
60
Issue
7
Pages
1008-1021
ISSN
  • 0018-7208 (ISSN-L)
  • 1547-8181
OpenAlex
W2810664371
Cited by
67
References
49
Citations by year
2026: 12 · 2025: 8 · 2024: 12 · 2023: 10 · 2022: 10 · 2021: 6 · 2020: 6 · 2019: 3
FWCI
5.09
Type
journal article
Language
en
Open access
closed
Locations
  • Human Factors The Journal of the Human Factors and Ergonomics Society (publishedVersion)
  • PubMed (publishedVersion)
Funders
HCF Research Foundation (Doctoral Scholarship)
Topics
  • Social Sciences › Psychology › Social Psychology › Human-Automation Interaction and Safety
  • Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
  • Health Sciences › Medicine › Family Practice › Clinical Reasoning and Diagnostic Skills
Keywords
automation bias, cognitive load, task complexity, electronic prescribing, clinical decision support, omission errors, commission errors, medical students, prescribing errors, sustained attention, cognitive resource allocation
MeSH terms
Adult, Female, Humans, Male, Man-Machine Systems, Memory, Short-Term, Task Performance and Analysis, Decision Support Systems, Clinical, Electronic Prescribing, Young Adult, Executive Function

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review