Improving Auditory Warning Design: Relationship between Warning Sound Parameters and Perceived Urgency
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper presents an experimental study of the effects of individual sound parameters on perceived (psychoacoustic) urgency. Experimental Series 1 showed that fundamental frequency, harmonic series, amplitude envelope shape, and delayed harmonics all have clear and consistent effects on perceived urgency. Experimental Series 2 showed that temporal and melodic parameters such as speed, rhythm, pitch range, and melodic structure also have clear and consistent effects on perceived urgency. The final experiment tested a set of 13 auditory warnings generated by an application of the earlier experimental findings. The urgency rank ordering of this warning set was predicted, and the correlation between the predicted and the obtained order was highly significant. The results of these experiments have a widespread application in the improvement of existing auditory warning systems and the design of new systems, where the psychoacoustic and psychological appropriateness of warnings could be enhanced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stevens, S. S. (1957) · Psychological Review · doi:10.1037/h0046162 · Cited by 3,361
Proceedings of the Institute of Acoustics 2014
Valentini-Botinhao, C., Yamagishi, J., & King, S. (2014) · Cited by 325
A General Procedure for Obtaining Paired Comparisons from Multiple Rank Orders
Gulliksen, H. O., & Tucker, L. R. (1961) · Psychometrika · doi:10.1007/bf02289713 · Cited by 67
Cited by
Human probability matching behaviour in response to alarms of varying reliability
BLISS, J. P., GILSON, R. D., & DEATON, J. E. (1995) · Ergonomics · doi:10.1080/00140139508925269 · Cited by 293
The effects of music tempo and loudness level on treadmill exercise
Edworthy, J., & Waring, H. (2006) · Ergonomics · doi:10.1080/00140130600899104 · Cited by 286
Self-citationAssessing the Effectiveness of Various Auditory Cues in Capturing a Driver's Visual Attention.
Ho, C., & Spence, C. (2005) · Journal of Experimental Psychology: Applied · doi:10.1037/1076-898x.11.3.157 · Cited by 228
“Edworthy et al., 1991; Horowitz & Dingus, 1992). In an elaborate early study of the relative effectiveness of various different auditory warning signals, Oyer and Hardick (1963) investigated the optimum acoustical dimensions of auditory alerting signals. Sounds including animal and human noises (such as elephants stam…”
BackgroundGRAHAM, R. (1999) · Ergonomics · doi:10.1080/001401399185108 · Cited by 223
Alarms and human behaviour: implications for medical alarms
Edworthy, J., & Hellier, E. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael114 · Cited by 185
Self-citation
Metadata
- Authors
- Edworthy, J., Loxley, S., & Dennis, I.
- Venue
- Human Factors: The Journal of the Human Factors and Ergonomics Society
- Publisher
- SAGE Publications
- Published
- 1991-04
- Volume
- 33
- Issue
- 2
- Pages
- 205-231
- ISSN
- 0018-7208 (ISSN-L)
- 1547-8181
- OpenAlex
- W1497286318
- Cited by
- 432
- References
- 3
- FWCI
- 20.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.