Visual Inspection for Caries Detection: A Systematic Review and Meta-analysis
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
We aimed to perform a systematic review including a meta-analysis to evaluate the overall accuracy of visual methods for detecting carious lesions and to identify possible sources of heterogeneity among the studies included. Two reviewers searched PubMed, Embase, Scopus, and other sources through July 2014 to identify published and nonpublished studies in English. Studies of visual inspection were included that 1) assessed accuracy of the method in detecting caries lesions; 2) were performed on occlusal, proximal, or free smooth surfaces in primary or permanent teeth; 3) had a reference standard; and 4) reported sufficient data about sample size and accuracy of methods. The data were used to calculate the pooled sensitivity, specificity, diagnostic odds ratio, and summary receiver operating characteristics curve. Heterogeneity of the studies was also assessed. A total of 102 manuscripts (from 5,808 articles initially identified) and 1 abstract (from 168) met the inclusion criteria. In general, the analysis demonstrated that the visual method had good accuracy for detecting caries lesions. Although laboratory and clinical studies have presented similar accuracy, clinically obtained specificity was higher. We also observed moderate to high heterogeneity and evidence of publication bias in most papers. Moreover, studies employing widely recognized visual scoring systems presented significantly better accuracy as compared to studies that used their own criteria. In conclusion, visual caries detection method has good overall performance. Furthermore, although the identified studies had high heterogeneity and risk of bias, the use of detailed and validated indices seems to improve the accuracy of the method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Regarding the reference standard methods, at initial caries lesions threshold, we observed a better performance in studies using operative intervention as a reference standard on occlusal surfaces of permanent teeth, probably due to incorporation bias (Lijmer et al., 1999), since teeth thought of as sound in such in v…”
BackgroundMethodDirection and impact of language bias in meta-analyses of controlled trials: empirical study
Jüni, P., Holenstein, F., Sterne, J., Bartlett, C., & Egger, M. (2002) · International Journal of Epidemiology · doi:10.1093/ije/31.1.115 · Cited by 892
An overview of clinical research: the lay of the land
Grimes, D. A., & Schulz, K. F. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07283-5 · Cited by 734 · cited 2×
“…demands when trying to keep up-to-date with the literature; issues such as lack of access to and time taken to keep abreast of the increasing scientific literature are some of the factors that prevent professionals from implementing the best evidence into clinical practice (Grimes and Schulz 2002).”
BackgroundSterne, J. A., Egger, M., & Moher, D. (2008) · Cochrane Handbook for Systematic Reviews of Interventions · doi:10.1002/9780470712184.ch10 · Cited by 651
Nyvad, B., Machiulskiene, V., & Baelum, V. (1999) · Caries Research · doi:10.1159/000016526 · Cited by 593
What contributions do languages other than English make on the results of meta-analyses?
Moher, D., Pham, Klassen, T. P., Schulz, K. F., Berlin, J. A., Jadad, A. R., & Liberati, A. (2000) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(00)00188-8 · Cited by 453
Cited by
Detecting caries lesions of different radiographic extension on bitewings using deep learning
Cantu, A. G., Gehrung, S., Krois, J., Chaurasia, A., Rossi, J. G., Gaudin, R., Elhennawy, K., & Schwendicke, F. (2020) · Journal of Dentistry · doi:10.1016/j.jdent.2020.103425 · Cited by 321
Cost-effectiveness of Artificial Intelligence for Proximal Caries Detection
Schwendicke, F., Rossi, J. G., Göstemeyer, G., Elhennawy, K., Cantu, A. G., Gaudin, R., Chaurasia, A., Gehrung, S., & Krois, J. (2021) · Journal of Dental Research · doi:10.1177/0022034520972335 · Cited by 152
In vivo validity of proximal caries detection in primary teeth, with histological validation
Subka, S., Rodd, H., Nugent, Z., & Deery, C. (2019) · International Journal of Paediatric Dentistry · doi:10.1111/ipd.12478 · Cited by 25
Self-citation
Metadata
- Authors
- Gimenez, T., Piovesan, C., Braga, M. M., Raggio, D. P., Deery, C., Ricketts, D. N., Ekstrand, K. R., & Mendes, F. M.
- Venue
- Journal of Dental Research
- Publisher
- SAGE Publications
- Published
- 2015-05-20
- Volume
- 94
- Issue
- 7
- Pages
- 895-904
- ISSN
- 0022-0345 (ISSN-L)
- 1544-0591
- OpenAlex
- W1591352166
- Cited by
- 203
- References
- 7
- FWCI
- 21.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.