Abstract

After the 2010 earthquake, Haiti committed to introducing 4 new antigens into its routine immunization schedule, which required improving its cold chain (ie, temperature-controlled supply chain) and increasing vaccine storage capacity by installing new refrigerators. We tested the feasibility of using remote temperature monitoring devices (RTMDs) in Haiti in a sample of vaccine refrigerators fueled by solar panels, propane gas, or electricity. We analyzed data from 16 RTMDs monitoring 24 refrigerators in 15 sites from March through August 2014. Although 5 of the 16 RTMDs exhibited intermittent data gaps, we identified typical temperature patterns consistent with refrigerator door opening and closing, propane depletion, thermostat insufficiency, and overstocking. Actual start-up, annual maintenance, and annual electricity costs for using RTMDs were $686, $179, and $9 per refrigerator, respectively. In Haiti, RTMD use was feasible. RTMDs could be prioritized for use with existing refrigerators with high volumes of vaccines and new refrigerators to certify their functionality before use. Vaccine vial monitors could provide additional useful information about cumulative heat exposure and possible vaccine denaturation.

Overview

CoChat Summary

TL;DR

This demonstration found that remote temperature monitoring devices (RTMDs) were feasible for monitoring vaccine refrigerators in Haiti, despite intermittent data gaps in some devices. RTMD data revealed temperature patterns consistent with door opening/closing, propane depletion, thermostat insufficiency, and overstocking, and costs were estimated per refrigerator.

Key findings

  • Of 16 RTMDs monitoring 24 refrigerators at 15 sites, 14 devices transmitted consistent data for 21 refrigerators; 5 devices had intermittent data gaps.
  • Temperature patterns were consistent with refrigerator door opening and closing, propane depletion, thermostat insufficiency, and overstocking, which reduced air circulation.
  • Actual costs per refrigerator in the demonstration were $686 start-up, $179 annual maintenance, and $9 annual electricity; if 1 RTMD monitored 4 or 8 refrigerators, estimated costs fell to $257/$67/$4 and $129/$34/$1, respectively.
  • The authors recommend prioritizing RTMDs for high-volume existing refrigerators, new refrigerators needing certification, and spot checks of refrigerators with prior excursions; vaccine vial monitors could supplement cumulative heat exposure information.

Methods

  • Test phase: in October 2013, RTMDs were installed in 1 solar and 2 propane refrigerators at 3 health facilities (1 urban, 2 rural) to test data collection and transmission.
  • Demonstration phase: from October 2013 through April 2014, 13 additional RTMDs were installed, totaling 16 devices at 15 sites in Ouest and Artibonite departments, monitoring 24 refrigerators (8 propane, 15 solar, 1 electric) at 10 peripheral and 5 intermediate storage locations.
  • The FridgeFone RTMD used 4 sensors (2 interior, 1 door jamb, 1 ambient), sampled every 10 minutes, and uploaded data via mobile networks; analysis covered March 1–August 16, 2014, examining excursions, ambient temperature, door status, and costs.

Limitations

  • Stated: results cannot be generalized to the nearly 700 vaccine refrigerators in all 10 of Haiti’s departments; the sample size of 16 RTMDs was limited by available funds.
  • Stated: the authors did not monitor or evaluate local responses to excursion alarms, and door monitors were prone to falling off or becoming disconnected, causing data gaps.
  • Stated: battery electricity costs were excluded because battery recharge frequency was unknown; evident from the text: the demonstration covered only 2 departments over a limited period, and cost estimates relied on manufacturer electricity use and a public government electricity rate.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1177/0033354917742119

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

5 Valid · 0 Not valid · 10 Not checked · 30 Own results and interpretations

22 more claims

Create a free account to see all 45 claims and to verify the 7 references still open.

See all claims — free account
  • It may state two separate claims as one. 9
  • Probably not a substantial claim. 11
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

1 of 1

Citations

Cites

Show all 6 references

Research works printed but not linked: 4

  1. 8. Haitian Ministry of Public Health and Population. Complete Multi-annual Plan for the Expanded Program on Immunization: CMAP EPI, 2011-2015 . Port-au-Prince, Haiti: Haitian Ministry of Public Health and Population; 2011.
  2. 9. Haitian Ministry of Public Health and Population. Assessment of Haiti's EPI Cold Chain and Logistics System . Port-au-Prince, Haiti: Haitian Ministry of Public Health and Population; 2011.
  3. 12. Sharma SK, Sharma Y, Kumar S, Sharma E. Vaccine vial monitors (VVMs): applications and challenges. Pharma Innov J . 2017;6(3):1-6.
  4. 15. Haitian Ministry of Public Health and Population. Physical Inventory of Cold Chain Equipment and Vehicles of the Haitian Health System [in French] . Port-au-Prince, Haiti: Haitian Ministry of Public Health and Population; 2013.

Cited by

See all 13

Metadata

Authors
Cavallaro, K. F., Francois, J., Jacques, R., Mentor, D., Yalcouye, I., Wilkins, K., Mueller, N., Turner, R., Wallace, A., & Tohme, R. A.
Affiliations
  • Centers for Disease Control and Prevention (US)
  • UNICEF Country Office, Port-au-Prince, Haiti
  • Ministère de la Santé Publique et de la Population (HT)
  • United Nations Children's Fund (US)
  • Expanded Program of Immunization, Ministry of Public Health and Population, Port-au-Prince, Haiti
  • ScaleStation, Meridian, ID, USA
Corresponding author
Cavallaro, Kathleen F.
Venue
Public Health Reports
Published
2017-12-20
Volume
133
Issue
1
Pages
39-44
ISSN
  • 0033-3549 (ISSN-L)
  • 1468-2877
OpenAlex
W2778512433
Cited by
13
References
6
Citations by year
2026: 2 · 2025: 2 · 2024: 3 · 2021: 5 · 2020: 1
FWCI
1.34
Type
journal article
Language
en
Open access
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Public Health Reports (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
UNICEF
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Quality and Safety in Healthcare
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Pharmaceutical Quality and Counterfeiting
  • Life Sciences › Agricultural and Biological Sciences › Food Science › Food Supply Chain Traceability
Keywords
vaccine refrigerators, cold chain, vaccine storage, Haiti, 2010 Haiti earthquake, solar-powered refrigerator, vaccine vial monitor
MeSH terms
Cold Temperature, Costs and Cost Analysis, Drug Storage, Haiti, Humans, Refrigeration, Vaccines, Remote Sensing Technology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-29, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-29 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Demonstration of the Use of Remote Temperature Monitoring Devices in Vaccine Refrigerators in Haiti. https://app.cochat.ai/papers/10.1177/0033354917742119
The paper
Cavallaro, K. F., Francois, J., Jacques, R., Mentor, D., Yalcouye, I., Wilkins, K., Mueller, N., Turner, R., Wallace, A., & Tohme, R. A. (2018). Demonstration of the Use of Remote Temperature Monitoring Devices in Vaccine Refrigerators in Haiti. Public Health Reports. https://doi.org/10.1177/0033354917742119

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.