Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 174

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

A systematic approach to occupancy modeling in ambient sensor-rich buildings

Yang, Zheng, Li, Nan, Becerik-Gerber, Burcin, Orosz, Michael · 2014 · SIMULATION

Abstract

With ever-rising energy demand and diminishing sources of inexpensive energy resources, energy conservation has become an increasingly important topic. Building heating, ventilation, and air conditioning (HVAC) systems are considered to be a prime target for energy conservation due to their significant contribution to commercial buildings’ energy consumption in the US. Knowing a building’s occupancy plays a crucial role in implementing demand-response HVAC controls, with a corresponding potential for reduction of HVAC energy consumption, especially in office buildings. This paper evaluates occupancy modeling (both binary detection and multi-class estimation) using twelve ambient sensor variables. Performance of six machine-learning techniques is evaluated in both single-occupancy and multi-occupancy offices. Of the six, the decision-tree technique yielded the best overall accuracy (i.e. 96.0% to 98.2%) and root mean square error (RMSE) (i.e. 0.109 to 0.156). The contribution of each individual ambient sensor variable is evaluated via information gain. It is found that CO 2, door status, and light variables have important contributions to the final modeling results. It is observed that the overall accuracy generally increases as the number of sensors increases. This paper also examines the possibility of building a global occupancy model, and explores the reasons for low performance of global occupancy estimation. Lastly, the occupancy model is used to estimate and visualize the accumulative room and thermal zone usage in an office test-bed building for three months. The results reveal that the effective vacancy accounts for a substantial portion of the operational hours, varying from 19.8% to 29.8% with an average of 23.3%, which bears significant potential for energy savings. Furthermore, the authors simulated HVAC energy consumption of the test-bed building for three months in DesignBuilder and EnergyPlus, and compared energy consumption of occupancy-based demand-response HVAC controls using the authors’ occupancy-modeling results to the conventional HVAC controls currently implemented in the test-bed building. The results demonstrate that 20% of gas and 18% of electricity could be effectively saved if occupancy-based demand-response HVAC control is implemented.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0037549713489918

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 174

Metadata

Authors
Yang, Z., Li, N., Becerik-Gerber, B., & Orosz, M.
Venue
SIMULATION
Published
2013-07-03
Volume
90
Issue
8
Pages
960-977
ISSN
  • 0037-5497 (ISSN-L)
  • 1741-3133
OpenAlex
W1994158003
Cited by
174
References
2
FWCI
12.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A systematic approach to occupancy modeling in ambient sensor-rich buildings. https://app.cochat.ai/papers/10.1177/0037549713489918
The paper
Yang, Z., Li, N., Becerik-Gerber, B., & Orosz, M. (2014). A systematic approach to occupancy modeling in ambient sensor-rich buildings. SIMULATION. https://doi.org/10.1177/0037549713489918

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.