The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Hyperglycemia Associated With High, Continuous Infusion Rates of Total Parenteral Nutrition Dextrose
Abstract
A retrospective study was performed to determine whether there is an increased incidence of hyperglycemia in patients not predisposed to hyperglycemia (n = 102) who receive total parenteral nutrition (TPN) dextrose in excess of 4 to 5 mg/kg/min. Of the 37 subjects administered dextrose at >5 mg/kg/min, 18 exhibited hyperglycemia. None did so who received dextrose at ≤4 mg/kg/min (n = 19). TPN dextrose infusion rate was positively correlated with blood glucose concentration, over and above other variables considered in a multiple regression, including kcal/kg administered, furosemide or dopamine use, gender, age, or diagnosis. Thus, TPN dextrose infusion rates > 4 to 5 mg/kg/min increase risk of hyperglycemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hypoglycemia in Hospitalized Patients
Fischer, K. F., Lees, J. A., & Newman, J. H. (1986) · New England Journal of Medicine · doi:10.1056/nejm198611133152002 · Cited by 309
Cited by
Management of diabetes and hyperglycemia in hospitals.
Clement, S., Braithwaite, S. S., Magee, M. F., Ahmann, A., Smith, E. P., Schafer, R. G., Hirsch, I. B., & on behalf of the Diabetes in Hospitals Writing Committee (2004) · Diabetes Care · doi:10.2337/diacare.27.2.553 · Cited by 1,266
McCowen, K. C., Malhotra, A., & Bistrian, B. R. (2001) · Critical Care Clinics · doi:10.1016/s0749-0704(05)70154-8 · Cited by 1,170
Guidelines for the Use of Parenteral and Enteral Nutrition in Adult and Pediatric Patients
American Society for Parenteral and Enteral Nutrition (2002) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607102026001011 · Cited by 755
Safe Practices for Parenteral Nutrition
Task Force for the Revision of Safe Practices for Parenteral Nutrition, Mirtallo, J., Canada, T., Johnson, D., Kumpf, V., Petersen, C., Sacks, G., Seres, D., & Guenter, P. (2004) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607104028006s39 · Cited by 397
Self-citationAlterations in fuel metabolism in critical illness: hyperglycaemia
Mizock, B. A. (2001) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1053/beem.2001.0168 · Cited by 380
Metadata
- Authors
- Rosmarin, D. K., Wardlaw, G. M., & Mirtallo, J.
- Venue
- Nutrition in Clinical Practice
- Publisher
- Wiley
- Published
- 1996-08
- Volume
- 11
- Issue
- 4
- Pages
- 151-156
- ISSN
- 0884-5336 (ISSN-L)
- 1941-2452
- OpenAlex
- W2037421018
- Cited by
- 175
- References
- 1
- FWCI
- 2.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hyperglycemia Associated With High, Continuous Infusion Rates of Total Parenteral Nutrition Dextrose. https://app.cochat.ai/papers/10.1177/0115426596011004151
- The paper
- Rosmarin, D. K., Wardlaw, G. M., & Mirtallo, J. (1996). Hyperglycemia Associated With High, Continuous Infusion Rates of Total Parenteral Nutrition Dextrose. Nutrition in Clinical Practice. https://doi.org/10.1177/0115426596011004151
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.