Abstract

This paper presents a robust model-based predictive control (MPC) strategy for temperature control of an air-conditioning system, which consists of multiple local-loop processes and each process suffers from different dynamics uncertainties or variations. When an appropriate sampling period is chosen to discretise the system for computer control, a state-space discrete model with an uncertainty polytope is developed to describe the mixing uncertainties of these type of systems. The main benefit of the proposed description is that robust model predictive control can be easily used to design a robust controller for such a system while taking account of constraints associated with this system. A linear matrix inequality-based MPC algorithm is employed for control design. Case study was conducted on a dynamic simulation platform of an air-conditioning system, which evaluated the developed strategy in various simulation tests by comparing with the conventional PID control. Results demonstrated that the developed strategy is able to deal with constraints and allows stable and robust control while maintaining acceptable thermal comfort. Although the strategy is illustrated and validated using a constant air volume air-conditioning system, it can be applied to other constraint HVAC processes suffering from similar uncertainties. Practical applications: The main benefit of the developed strategy (including the proposed description and the adopted robust control algorithm) for practical application is that uncertainties and constraints can be dealt with simultaneously in one framework. Constraints in HVAC systems exist due to the application of actuators, for example, the rate limit considered in the paper. Taking account of constraints is useful to prevent unnecessary damages to equipments and maintain the system operating in a safe mode. Most importantly, the control objectives can be achieved in a constraint manner. The consideration of uncertainties, probably due to the changes of operating environment, is useful to release the work of accurate modelling of HVAC processes and online tuning of controllers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0143624409352420

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 46

Metadata

Authors
Xu, X., Wang, S., & Huang, G.
Venue
Building Services Engineering Research and Technology
Published
2010-01-14
Volume
31
Issue
1
Pages
39-55
ISSN
  • 0143-6244 (ISSN-L)
  • 1477-0849
OpenAlex
W2127654248
Cited by
46
References
0
FWCI
6.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Robust MPC for temperature control of air-conditioning systems concerning on constraints and multitype uncertainties. https://app.cochat.ai/papers/10.1177/0143624409352420
The paper
Xu, X., Wang, S., & Huang, G. (2010). Robust MPC for temperature control of air-conditioning systems concerning on constraints and multitype uncertainties. Building Services Engineering Research and Technology. https://doi.org/10.1177/0143624409352420

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.